EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of the modified Masood's scoring index versus international academy of cytology Yokohama system in the categorization of breast fine needle aspirates

Adil Aziz Khan iD, Sana Ahuja iD, Shakthivel V, Sufian Zaheer iD, Sunil Ranga

Cytopathology · 2024

DOI: 10.1111/cyt.13432 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Cytopathology, 2024. Verfasst von Adil Aziz Khan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India. Hauptthemen laut MEDLINE: Breast Neoplasms, Breast, Cytodiagnosis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Context

The Modified Masood Scoring Index (MMSI) categorizes breast fine needle aspirates into four categories non‐proliferative breast diseases (PBD), PBD without atypia, PBD with atypia and carcinoma in situ/carcinoma. The International Academy of Cytology Yokohama System classifies the aspirates into five categories – inadequate, benign, atypical, suspicious, and malignant. Very few studies have been conducted so far to compare the diagnostic accuracy of this system.

Aims

The objectives of the study were to classify breast fine needle aspirates according to the MMSI and IAC Yokohama and assess their risk of malignancy (ROM) and performance parameters. Materials and Methods All breast FNAs received from June 2020 to May 2023 were classified according to the MMSI and IAC Yokohama. Using histopathological diagnosis as the gold standard, ROM and performance parameters were calculated.

Results

Out of the 559 breast fine needle aspirates, the histopathological correlation was available for 337 cases. The ROM for non‐PBD, PBD without atypia, PBD with atypia and carcinoma in situ/carcinoma categories were 0%, 1.2%, 9.1% and 93%, respectively. The ROM for each of the categories of Yokohama system was 16.6%, 1.1%, 4.3%, 86.2% and 97.6%, respectively. The values for the sensitivity, specificity, PPV, NPV and diagnostic accuracy were slightly higher for IAC Yokohama (97.3%, 97.2%, 94.7%, 98.6% and 97.2%, respectively) than the MMSI (96.4%, 96.2%, 93%, 98.1% and 96.3%, respectively). Furthermore, another shortfall of MMSI is the inability to compare the Inadequate category of the Yokohama system.

Conclusion

Overall Yokohama system proved to be a better system for categorizing breast lesions on FNAB as the scoring system provides more objective categorization and minimizes false positive and false negative cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsBreastCytodiagnosisHumansBiopsy, Fine-NeedleFemaleMiddle AgedAdultAgedAged, 80 and over

Stichwörter der Autor:innen

Yokohama systembreast cancerdiagnostic accuracymodified Masood scoring index

Autor:innen und Institutionen

  • Department of Pathology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India.

ORCID-Profile: Adil Aziz Khan, Sana Ahuja, Sufian Zaheer

Zitieren

APA

Khan, A. A., Ahuja, S., V, S., Zaheer, S., & Ranga, S. (2024). Comparison of the modified Masood's scoring index versus international academy of cytology Yokohama system in the categorization of breast fine needle aspirates. Cytopathology. https://doi.org/10.1111/cyt.13432

Vancouver

Khan AA, Ahuja S, V S, Zaheer S, Ranga S. Comparison of the modified Masood's scoring index versus international academy of cytology Yokohama system in the categorization of breast fine needle aspirates. Cytopathology. 2024. doi:10.1111/cyt.13432

BibTeX
@article{Khan2024,
  author = {Khan, Adil Aziz and Ahuja, Sana and V, Shakthivel and Zaheer, Sufian and Ranga, Sunil},
  title = {Comparison of the modified Masood's scoring index versus international academy of cytology Yokohama system in the categorization of breast fine needle aspirates},
  journal = {Cytopathology},
  year = {2024},
  doi = {10.1111/cyt.13432}
}
Kostenlos starten →