Variational autoencoders for generative modeling of drug dosing determinants in renal, hepatic, metabolic, and cardiac disease states
Clinical and Translational Science · 2024
DOI: 10.1111/cts.13872 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Translational Science, 2024. Verfasst von Raginee R Titar und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Sciences, University at Buffalo, The State University of New York, Buffalo, New York, USA. Hauptthemen laut MEDLINE: Heart Diseases, Kidney Diseases, Biomarkers. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Physiological determinants of drug dosing (PDODD) are a promising approach for precision dosing. This study investigates the alterations of PDODD in diseases and evaluates a variational autoencoder (VAE) artificial intelligence model for PDODD. The PDODD panel contained 20 biomarkers, and 13 renal, hepatic, diabetes, and cardiac disease status variables. Demographic characteristics, anthropometric measurements (body weight, body surface area, waist circumference), blood (plasma volume, albumin), renal (creatinine, glomerular filtration rate, urine flow, and urine albumin to creatinine ratio), and hepatic (R‐value, hepatic steatosis index, drug‐induced liver injury index), blood cell (systemic inflammation index, red cell, lymphocyte, neutrophils, and platelet counts) biomarkers, and medical questionnaire responses from the National Health and Nutrition Examination Survey (NHANES) were included. The tabular VAE (TVAE) generative model was implemented with the Synthetic Data Vault Python library. The joint distributions of the generated data vs. test data were compared using graphical univariate, bivariate, and multidimensional projection methods and distribution proximity measures. The PDODD biomarkers related to disease progression were altered as expected in renal, hepatic, diabetes, and cardiac diseases. The continuous PDODD panel variables generated by the TVAE satisfactorily approximated the distribution in the test data. The TVAE‐generated distributions of some discrete variables deviated from the test data distribution. The age distribution of TVAE‐generated continuous variables was similar to the test data. The TVAE algorithm demonstrated potential as an AI model for continuous PDODD and could be useful for generating virtual populations for clinical trial simulations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Pharmaceutical Sciences, University at Buffalo, The State University of New York, Buffalo, New York, USA.
Zitieren
APA
Titar, R. R., & Ramanathan, M. (2024). Variational autoencoders for generative modeling of drug dosing determinants in renal, hepatic, metabolic, and cardiac disease states. Clinical and Translational Science. https://doi.org/10.1111/cts.13872
Vancouver
Titar RR, Ramanathan M. Variational autoencoders for generative modeling of drug dosing determinants in renal, hepatic, metabolic, and cardiac disease states. Clinical and Translational Science. 2024. doi:10.1111/cts.13872
BibTeX
@article{Titar2024,
author = {Titar, Raginee R and Ramanathan, Murali},
title = {Variational autoencoders for generative modeling of drug dosing determinants in renal, hepatic, metabolic, and cardiac disease states},
journal = {Clinical and Translational Science},
year = {2024},
doi = {10.1111/cts.13872}
}
EUVIMED