EUVIMEDEUVIMED entdecken
Crossref

Outcomes of Donor‐Recipient Size Mismatch in Donation After Circulatory Death Heart Transplantation

Iris Feng iD, Kavya Rajesh iD, Yanling Zhao, Farhana Latif, Gabriel T Sayer, Nir Y Uriel, Yoshifumi Naka, Paul A Kurlansky iD, Koji Takeda iD

Clinical Transplantation · 2025

DOI: 10.1111/ctr.70232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Transplantation, 2025. Verfasst von Iris Feng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Department of Surgery, Columbia University Irving Medical Center, New York, New York, USA. Hauptthemen laut MEDLINE: Heart Transplantation, Tissue Donors, Tissue and Organ Procurement, Transplant Recipients. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Prior studies of donor‐recipient size mismatch only included donation after brain death heart transplants. Given higher rates of primary graft dysfunction, identifying optimal graft selection factors specific to donation after circulatory death (DCD) is crucial. We assessed outcomes of size mismatch in DCD heart transplants based on predicted heart mass (PHM), height, and weight.

Methods

The study cohort consisted of 1631 adult patients from the United Network for Organ Sharing dataset who underwent DCD heart transplant between 12/1/2019 and 6/30/2024. Size mismatch was categorized based on donor/recipient ratio: >15% difference for weight and PHM, and >5% difference for height. The primary outcome was post‐transplant mortality. Median follow‐up time was 359 days with an interquartile range of 165.2–677.5 days.

Results

Stratification by height mismatch resulted in 257 (15.8%) undersized, 1062 (65.1%) size‐matched, and 312 (19.1%) oversized donor‐recipient pairs. Multivariable logistic regression analysis found that oversized height was independently associated with a significantly greater risk of in‐hospital mortality (OR [95% CI]: 2.106 [1.161, 3.822], p = 0.014), while weight and PHM mismatch remained non‐significant. Multivariable Cox regression was also performed for longer term mortality by including all mortality events through time of last follow‐up, and again found that oversized height was independently associated with the outcome (HR [95% CI]: 1.737 [1.181, 2.555], p = 0.005) while weight and PHM mismatch were not.

Conclusions

Donor‐recipient height oversizing by >5% was associated with a greater risk of early and mid‐term mortality after DCD heart transplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart TransplantationTissue DonorsTissue and Organ ProcurementTransplant RecipientsDonor SelectionPostoperative ComplicationsGraft RejectionHumansFemaleMaleMiddle AgedFollow-Up StudiesPrognosisAdultRisk FactorsGraft SurvivalSurvival RateRetrospective StudiesHospital MortalityOrgan Size

Stichwörter der Autor:innen

donation after circulatory deathdonor oversizingdonor‐recipient size matchheart transplantationpredicted heart mass

Autor:innen und Institutionen

  • Division of Cardiac Surgery, Department of Surgery, Columbia University Irving Medical Center, New York, New York, USA.
  • Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA.
  • Center of Innovation and Outcomes Research, Department of Surgery, Columbia University, New York, New York, USA.

ORCID-Profile: Iris Feng, Kavya Rajesh, Paul A Kurlansky, Koji Takeda

Zitieren

APA

Feng, I., Rajesh, K., Zhao, Y., Latif, F., Sayer, G. T., Uriel, N. Y., Naka, Y., Kurlansky, P. A., & Takeda, K. (2025). Outcomes of Donor‐Recipient Size Mismatch in Donation After Circulatory Death Heart Transplantation. Clinical Transplantation. https://doi.org/10.1111/ctr.70232

Vancouver

Feng I, Rajesh K, Zhao Y, Latif F, Sayer GT, Uriel NY, et al. Outcomes of Donor‐Recipient Size Mismatch in Donation After Circulatory Death Heart Transplantation. Clinical Transplantation. 2025. doi:10.1111/ctr.70232

BibTeX
@article{Feng2025,
  author = {Feng, Iris and Rajesh, Kavya and Zhao, Yanling and Latif, Farhana and Sayer, Gabriel T and Uriel, Nir Y and Naka, Yoshifumi and Kurlansky, Paul A and Takeda, Koji},
  title = {Outcomes of Donor‐Recipient Size Mismatch in Donation After Circulatory Death Heart Transplantation},
  journal = {Clinical Transplantation},
  year = {2025},
  doi = {10.1111/ctr.70232}
}
Kostenlos starten →