Disposable grasper‐integrated flexible cystoscope for ureteral stent removal in transplanted patients; focus on feasibility, safety, and patient experience. Results and micro‐cost analysis from a tertiary referral center
Clinical Transplantation · 2024
DOI: 10.1111/ctr.15321 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Transplantation, 2024. Verfasst von Andrea Bosio und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, AOU Città della Salute e della Scienza, Molinette University Hospital, Turin, Italy. Hauptthemen laut MEDLINE: Kidney Transplantation, Stents, Feasibility Studies, Device Removal. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
Introduction & objectives To evaluate ureteral stent removal (SR) using a grasper‐integrated disposable flexible cystoscope (giFC—Isiris ®, Coloplast ®) after kidney transplantation (KT), with a focus on feasibility, safety, patient experience, and costs. Material and methods All consecutive KT undergoing SR through giFC were prospectively enrolled from January 2020 to June 2023. Patient characteristics, KT and SR details, urine culture results, antimicrobial prescriptions, and the incidence of urinary tract infections (UTI) within 1 month were recorded. A micro‐cost analysis was conducted, making a comparison with the costs of SR with a reusable FC and grasper.
Results
A total of 136 KT patients were enrolled, including both single and double KT, with 148 stents removed in total. The median indwelling time was 34 days [26, 47]. SR was successfully performed in all cases. The median preparation and procedure times were 4 min [3,5]. and 45 s[30, 60], respectively. The median Visual Analog Scale (VAS) score was 3 [1, 5], and 98.2% of patients expressed willingness to undergo the procedure again. Only one episode of UTI involving the graft (0.7%) was recorded. Overall, the estimated cost per SR procedure with Isiris ® and the reusable FC was 289.2€ and 151,4€, respectively.
Conclusions
This prospective series evaluated the use of Isiris ® for SR in a cohort of KT patients, demonstrating feasibility and high tolerance. The UTI incidence was 0.7% within 1 month. Based on the micro‐cost analysis, estimated cost per procedure favored the reusable FC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, AOU Città della Salute e della Scienza, Molinette University Hospital, Turin, Italy.
- Department of Nephrology, Dialysis and Transplantation, AOU Città della Salute e della Scienza, Molinette University Hospital, Turin, Italy.
ORCID-Profile: Andrea Bosio
Zitieren
APA
Bosio, A., Alessandria, E., Gozzo, C., Vercelli, E., Micai, L., Bertello, G., Pasquale, G., Sedigh, O., Oderda, M., Biancone, L., & Gontero, P. (2024). Disposable grasper‐integrated flexible cystoscope for ureteral stent removal in transplanted patients; focus on feasibility, safety, and patient experience. Results and micro‐cost analysis from a tertiary referral center. Clinical Transplantation. https://doi.org/10.1111/ctr.15321
Vancouver
Bosio A, Alessandria E, Gozzo C, Vercelli E, Micai L, Bertello G, et al. Disposable grasper‐integrated flexible cystoscope for ureteral stent removal in transplanted patients; focus on feasibility, safety, and patient experience. Results and micro‐cost analysis from a tertiary referral center. Clinical Transplantation. 2024. doi:10.1111/ctr.15321
BibTeX
@article{Bosio2024,
author = {Bosio, Andrea and Alessandria, Eugenio and Gozzo, Claudia and Vercelli, Eugenia and Micai, Luca and Bertello, Glauco and Pasquale, Giovanni and Sedigh, Omidreza and Oderda, Marco and Biancone, Luigi and Gontero, Paolo},
title = {Disposable grasper‐integrated flexible cystoscope for ureteral stent removal in transplanted patients; focus on feasibility, safety, and patient experience. Results and micro‐cost analysis from a tertiary referral center},
journal = {Clinical Transplantation},
year = {2024},
doi = {10.1111/ctr.15321}
}
EUVIMED