Correlation of FE NO With Spirometric Measurements and Blood Eosinophil Level in Patients With Severe Asthma
The Clinical Respiratory Journal · 2025
DOI: 10.1111/crj.70094 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Clinical Respiratory Journal, 2025. Verfasst von Wang Chun Kwok und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Queen Mary Hospital, The University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China. Hauptthemen laut MEDLINE: Asthma, Eosinophils, Spirometry, Nitric Oxide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sanofi Hong Kong.
Abstract (Originalsprache)
Background
Fractional exhaled nitric oxide (FE NO ) serves as a marker of eosinophil‐mediated airway inflammation and has been used in asthma diagnosis, phenotyping, and guidance regarding selection and adjustment of asthma therapy. Studies suggested that FE NO correlated with asthma symptoms, peripheral blood eosinophil level, blood IgE level, and spirometry indicators of airway obstruction. However, the results are inconsistent across studies.
Methods
A prospective cross‐sectional study was conducted in Queen Mary Hospital among adult patients with severe asthma. Patients had spirometry with bronchodilator reversibility and same‐day FE NO . Asthma control test (ACT) score and blood eosinophil and total IgE levels were measured within 4 weeks of FE NO and spirometry. The primary outcome was the correlation of FE NO and spirometric values. The secondary outcomes included the correlation of FE NO with ACT score, blood eosinophil, and total IgE levels.
Results
One hundred thirty‐five severe asthma patients with FE NO performed were included in the study. FE NO was negatively correlated with pre‐bronchodilator FEV 1 (L) ( r = −0.188, p = 0.029), pre‐bronchodilator FEV 1 (% predicted) ( r = −0.169, p = 0.050), pre‐bronchodilator FEV1/FVC ratio ( r = −0.269, p = 0.002), and post‐bronchodilator FEV 1 /FVC ( r = −0.215, p = 0.018). FE NO was positively correlated with bronchodilator reversibility (mL) ( r = 0.248, p = 0.006) and bronchodilator reversibility (%) ( r = 0.823, p = 0.002) , baseline blood eosinophil level by absolute cell count ( r = 0.308, p < 0.001) and by percentage ( r = 0.361, p < 0.001).
Conclusion
In adult patients with severe asthma, FE NO might have a negative correlation with the FEV 1 , FEV 1 /FVC ratio, and a positive correlation with bronchodilator reversibility, as well as with blood eosinophil levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Queen Mary Hospital, The University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China.
Förderung
- Sanofi Hong Kong
Zitieren
APA
Kwok, W. C., Ip, M. S. M., Tam, T. C. C., Ho, J. C. M., Lam, D. C. L., & Wang, K. L. J. (2025). Correlation of FE NO With Spirometric Measurements and Blood Eosinophil Level in Patients With Severe Asthma. The Clinical Respiratory Journal. https://doi.org/10.1111/crj.70094
Vancouver
Kwok WC, Ip MSM, Tam TCC, Ho JCM, Lam DCL, Wang KLJ. Correlation of FE NO With Spirometric Measurements and Blood Eosinophil Level in Patients With Severe Asthma. The Clinical Respiratory Journal. 2025. doi:10.1111/crj.70094
BibTeX
@article{Kwok2025,
author = {Kwok, Wang Chun and Ip, Mary Sau Man and Tam, Terence Chi Chun and Ho, James Chung Man and Lam, David Chi Leung and Wang, Kwan Ling Julie},
title = {Correlation of FE NO With Spirometric Measurements and Blood Eosinophil Level in Patients With Severe Asthma},
journal = {The Clinical Respiratory Journal},
year = {2025},
doi = {10.1111/crj.70094}
}
EUVIMED