A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease
The Clinical Respiratory Journal · 2023
DOI: 10.1111/crj.13654 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift The Clinical Respiratory Journal, 2023. Verfasst von Kohei Shikano und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan. Hauptthemen laut MEDLINE: Lung Diseases, Interstitial, Pneumothorax. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Secondary spontaneous pneumothorax (SSP) occurs as one of the complications associated with interstitial pneumonia (IP). Chest drainage is performed when there is a large volume of air in the pleural space. Notably, SSP with IP (SSP‐IP) is frequently not curable by chest drainage only. A digital drainage system (DDS) provides an objective evaluation of air leakage and maintains a pre‐determined negative pressure, compared to an analog drainage system (ADS). Few studies have reported the effectiveness of DDS in the treatment of SSP‐IP. This study aimed to assess the usefulness of DDS for SSP‐IP.
Methods
This retrospective study included patients with SSP‐IP who had undergone chest drainage. We reviewed the included patients' medical records, laboratory data, computed tomography findings, and pulmonary function data.
Results
DDS was used in 24 patients and ADS in 49 patients. The mean duration of chest drainage was 11.4 ± 1.9 days in the DDS group and 14.2 ± 1.3 days in the ADS group, which was not significantly different ( p = 0.218). Surgery, pleurodesis, and/or factor XIII administration were performed in 40 patients. Additionally, five (20.8%) patients in the DDS group and nine (18.4%) in the ADS group had a recurrence of pneumothorax within 4 weeks ( p = 1.000). One patient (14%) in the DDS group and six (12.2%) in the ADS group ( p = 0.414) were cured of pneumothorax but later died.
Conclusion
DDS did not demonstrate a significant difference in the shortening of chest drainage duration. Further study is needed to validate the results of this study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan.
- Department of Pulmonary Medicine, Seirei Hamamatsu General Hospital, Shizuoka, Japan.
ORCID-Profile: Kohei Shikano, Mitsuhiro Abe
Zitieren
APA
Shikano, K., Abe, M., Hirama, R., Kitahara, S., Maruyama, K., Horiuchi, D., Sakuma, N., Ishii, D., Kawasaki, T., Nakamura, H., & Suzuki, T. (2023). A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease. The Clinical Respiratory Journal. https://doi.org/10.1111/crj.13654
Vancouver
Shikano K, Abe M, Hirama R, Kitahara S, Maruyama K, Horiuchi D, et al. A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease. The Clinical Respiratory Journal. 2023. doi:10.1111/crj.13654
BibTeX
@article{Shikano2023,
author = {Shikano, Kohei and Abe, Mitsuhiro and Hirama, Ryutaro and Kitahara, Shinsuke and Maruyama, Kanae and Horiuchi, Dai and Sakuma, Noriko and Ishii, Daisuke and Kawasaki, Takeshi and Nakamura, Hidenori and Suzuki, Takuji},
title = {A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease},
journal = {The Clinical Respiratory Journal},
year = {2023},
doi = {10.1111/crj.13654}
}
EUVIMED