Application of conventional ultrasound‐based carotid grading system in assessing disease activity and monitoring progression in Takayasu arteritis

Xuelan Li iD, Chenyang Zhao iD, Juan Du, Fengju Liu, Jie Chen

Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)

DOI: 10.1111/cpf.70077 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 29.06.2026. Verfasst von Xuelan Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Comprehensive Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Takayasu Arteritis, Ultrasonography, Carotid Arteries, Carotid Arteries, Carotid Artery Diseases. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to evaluate and validate the utility of a conventional ultrasound‐based carotid grading system in assessing disease activity in Takayasu arteritis (TA) with carotid artery involvement, distinguishing between active and inactive patients, and monitoring therapeutic response.

Methods

The 108 patients were classified into the clinically‐active group (CAG) and the clinically‐inactive group (CIG), and were further classified into Grades I–V according to carotid ultrasound imaging characteristics, with Grades I, II, and V categorized as the ultrasound‐active group (UAG), and Grades III and IV as the ultrasound‐inactive group (UIG). Intergroup differences were compared, and the diagnostic performance of the ultrasound grading system for disease activity was evaluated by the ROC curve analysis. Treatment response assessed in 68 follow‐up patients based on ultrasound grading.

Results

The CAG exhibited higher inflammatory markers and greater carotid wall thickness ( p < 0.05). Grades I, II, and V predominated in the CAG, whereas Grades III and IV were more frequent in the CIG. Compared to the UIG, the UAG showed significantly elevated ESR, CRP, C3, and IgM, and thicker carotid walls ( p < 0.05). The ultrasound grading system achieved an AUC of 0.710 for identifying clinical activity in TA. Combined with carotid wall thickness, diagnostic performance surpassed either parameter alone. Among 68 follow‐up patients, the UAG had higher inflammatory markers and greater wall thickness at baseline but demonstrated more pronounced improvement in disease activity after treatment.

Conclusions

Conventional ultrasound is a reliable tool for characterizing vascular wall inflammation and monitoring therapeutic response in TA patients with carotid artery involvement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Takayasu ArteritisUltrasonography, Carotid ArteriesCarotid ArteriesCarotid Artery DiseasesHumansFemalePredictive Value of TestsSeverity of Illness IndexReproducibility of ResultsDisease ProgressionMaleAdultTreatment OutcomeBiomarkersYoung AdultROC CurveInflammation MediatorsMiddle Aged

Stichwörter der Autor:innen

Takayasu arteritisconventional ultrasoundtreatment monitoringultrasound grading systemvascular inflammation

Substanzen

BiomarkersInflammation Mediators

Autor:innen und Institutionen

  • Department of Comprehensive Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China.
  • Department of Rheumatology and Immunology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

ORCID-Profile: Xuelan Li, Chenyang Zhao

Förderung

  • None

Zitieren

APA

Li, X., Zhao, C., Du, J., Liu, F., & Chen, J. (2026). Application of conventional ultrasound‐based carotid grading system in assessing disease activity and monitoring progression in Takayasu arteritis. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70077

Vancouver

Li X, Zhao C, Du J, Liu F, Chen J. Application of conventional ultrasound‐based carotid grading system in assessing disease activity and monitoring progression in Takayasu arteritis. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70077

BibTeX
@article{Li2026,
  author = {Li, Xuelan and Zhao, Chenyang and Du, Juan and Liu, Fengju and Chen, Jie},
  title = {Application of conventional ultrasound‐based carotid grading system in assessing disease activity and monitoring progression in Takayasu arteritis},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  volume = {46},
  number = {4},
  doi = {10.1111/cpf.70077}
}
Kostenlos starten →