EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of hydrorelease on the mechanical properties of muscle and fascia: A study using ultrasonic shear wave elastography

Gakuto Nakao iD, Kousuke Shiwaku, Risa Adachi, Taiki Kodesho, Keigo Taniguchi, Hidenori Otsubo

Clinical Physiology and Functional Imaging · 2026

DOI: 10.1111/cpf.70052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, 2026. Verfasst von Gakuto Nakao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Sapporo Medical University, Sapporo, Japan. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Fascia, Muscle, Skeletal, Lidocaine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Recent studies have shown that hydrorelease reduces gliding resistance around nerves and between fascia, alleviating pain. However, the effects of hydrorelease on the mechanical properties of muscle and fascia remain unclear. This study aimed to examine changes in the mechanical properties of muscle and fascia before and after hydrorelease.

Methods

Twelve consecutive patients with ultrasound‐confirmed thickening or stacking of fascia and tenderness were included. The hydrorelease was performed under ultrasound guidance using a 25‐G, 40‐mm needle in‐plane technique, using 6 mL of saline containing 0.17% lidocaine at a concentration insufficient to produce an anaesthetic effect. The shear modulus and tenderness were measured before and after hydrorelease. The shear modulus was measured using ultrasonic shear wave elastography at two points on the muscle and fascia in the slacked and extended positions. Tenderness was evaluated for pain using the numeric rating scale. Wilcoxon signed‐rank test compared pain levels before and after hydrorelease. A two‐way analysis of variance (ANOVA) was performed for the shear modulus, with time (pre and post) and position (slacked and extended) as factors.

Results

Tenderness significantly decreased after hydrorelease ( p < 0.01). A two‐way ANOVA revealed a significant interaction (time × position) for the shear modulus in both muscle and fascia ( p < 0.01). Post‐hoc test results indicated no change in the shear modulus in the slacked position; however, a significant decrease was observed in the extended position after hydrorelease.

Conclusion

In summary, hydrorelease reduced the shear modulus of fascia and muscle during elongation, decreasing tissue stress.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesFasciaMuscle, SkeletalLidocaineAnesthetics, LocalMyalgiaSaline SolutionHumansFemaleMaleMiddle AgedAdultPredictive Value of TestsBiomechanical PhenomenaUltrasonography, InterventionalPain MeasurementTime FactorsTreatment OutcomeElastic ModulusAged

Stichwörter der Autor:innen

fasciahydroreleasemechanical propertiesultrasonic shear wave elastography

Substanzen

LidocaineAnesthetics, LocalSaline Solution

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Sapporo Medical University, Sapporo, Japan.
  • Professional Post-secondary Course (Physical Therapist), Sapporo Medical Technology, Welfare and Dentistry Professional Training College of Nishino Gakuen School Foundation, Sapporo, Japan.
  • Department of Orthopaedic Surgery, School of Medicine, Sapporo Medical University, Sapporo, Japan.
  • Department of Orthopedic, KKR Sapporo Medical Center, Sapporo, Japan.
  • Department of Sport Science and Research, Japan Institute of Sports Sciences (JISS), Tokyo, Japan.
  • Department of Physical Therapy, School of Health Sciences, Sapporo Medical University, Sapporo, Japan.

ORCID-Profile: Gakuto Nakao

Zitieren

APA

Nakao, G., Shiwaku, K., Adachi, R., Kodesho, T., Taniguchi, K., & Otsubo, H. (2026). Effects of hydrorelease on the mechanical properties of muscle and fascia: A study using ultrasonic shear wave elastography. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70052

Vancouver

Nakao G, Shiwaku K, Adachi R, Kodesho T, Taniguchi K, Otsubo H. Effects of hydrorelease on the mechanical properties of muscle and fascia: A study using ultrasonic shear wave elastography. Clinical Physiology and Functional Imaging. 2026. doi:10.1111/cpf.70052

BibTeX
@article{Nakao2026,
  author = {Nakao, Gakuto and Shiwaku, Kousuke and Adachi, Risa and Kodesho, Taiki and Taniguchi, Keigo and Otsubo, Hidenori},
  title = {Effects of hydrorelease on the mechanical properties of muscle and fascia: A study using ultrasonic shear wave elastography},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  doi = {10.1111/cpf.70052}
}
Kostenlos starten →