EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ventilation/perfusion SPECT in children: Feasibility, impact on clinical decision‐making and interrater agreement

Lise Borgwardt iD, Mette Louise Mørk, Henrik Gutte, Anne Kiil Berthelsen, Robin de Nijs, Ronan M G Berg iD, Jann Mortensen

Clinical Physiology and Functional Imaging · 2025

DOI: 10.1111/cpf.70012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, 2025. Verfasst von Lise Borgwardt und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Clinical Decision-Making, Ventilation-Perfusion Ratio, Ventilation-Perfusion Scan. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

It remains to be established whether it provides any clinical or diagnostic benefits to perform ventilation/perfusion (V/Q) scintigraphy as a single photon emission computed tomography in children. Here, we report our experience with this modality, evaluate its impact on clinical decision‐making and assess its interrater agreement.

Methods

All V/Q scintigraphies performed in children over a 1‐year period were identified, and patient files were reviewed. Two nuclear medicine physicians, blinded to patient data and each other's readings, interpreted all scintigraphies.

Results

A total of 20 planar and SPECT V/Q scintigraphies were identified. In 17/20 cases (85%), the results of the scan were found to directly inform clinical decision‐making. SPECT mainly ruled out the presence of ventilation and perfusion defects that were suspected on planar scintigraphy. In terms of interrater agreement, Cohen's ϰ coefficients for planar ventilation and perfusion scintigraphy were 0.34 and 0.38 (fair agreement), respectively, while the corresponding values for SPECT were 0.42 and 0.61 (moderate to substantial agreement).

Conclusion

It is both feasible and clinically meaningful to perform V/Q SPECT in children. In this patient group, V/Q SPECT furthermore seems to have better interrater agreement than planar scintigraphy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Emission-Computed, Single-PhotonClinical Decision-MakingVentilation-Perfusion RatioVentilation-Perfusion ScanLungHumansFeasibility StudiesChildFemaleMaleReproducibility of ResultsObserver VariationChild, PreschoolPredictive Value of TestsInfantAdolescentRetrospective StudiesAge Factors

Stichwörter der Autor:innen

interrater agreementlung diseasepaediatric SPECT/CTpaediatric nuclear medicinepulmonary imaging

Autor:innen und Institutionen

  • Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
  • Department of Radiology, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
  • Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Centre for Physical Activity Research, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
  • Department of Medicine, The National Hospital, Torshavn, Faroe Islands.

ORCID-Profile: Lise Borgwardt, Ronan M G Berg

Zitieren

APA

Borgwardt, L., Mørk, M. L., Gutte, H., Berthelsen, A. K., de Nijs, R., Berg, R. M. G., & Mortensen, J. (2025). Ventilation/perfusion SPECT in children: Feasibility, impact on clinical decision‐making and interrater agreement. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70012

Vancouver

Borgwardt L, Mørk ML, Gutte H, Berthelsen AK, de Nijs R, Berg RMG, et al. Ventilation/perfusion SPECT in children: Feasibility, impact on clinical decision‐making and interrater agreement. Clinical Physiology and Functional Imaging. 2025. doi:10.1111/cpf.70012

BibTeX
@article{Borgwardt2025,
  author = {Borgwardt, Lise and Mørk, Mette Louise and Gutte, Henrik and Berthelsen, Anne Kiil and de Nijs, Robin and Berg, Ronan M G and Mortensen, Jann},
  title = {Ventilation/perfusion SPECT in children: Feasibility, impact on clinical decision‐making and interrater agreement},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2025},
  doi = {10.1111/cpf.70012}
}
Kostenlos starten →