EUVIMEDEUVIMED entdecken
Vergleichsstudie

Diaphragm thickness and physical performance in regular smokers and non‐smokers: A pilot study

Bahar Özgül, Zübeyir Sarı, İlkşan Demirbüken, Hilal Başak Can, Zana Gezer, Halil Yıldırım, Mine Gülden Polat

Clinical Physiology and Functional Imaging · 2025

DOI: 10.1111/cpf.70003 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, 2025. Verfasst von Bahar Özgül und 6 weiteren Autor:innen. Beteiligte Einrichtung: Marmara University Health Sciences Faculty Physiotherapy and Rehabilitation Department, Istanbul, Turkey. Hauptthemen laut MEDLINE: Diaphragm, Smokers, Non-Smokers, Muscle Strength. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Marmara Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite the understanding of the role of diaphragm role as a crucial element in trunk stabilizer performance, limited research has been carried out on the diaphragmatic features particularly in smoking population.

Objectives

It was aimed to compare the diaphragm structure beside trunk stabilizer performance & body balance of young regular smokers and non‐smokers and investigate the relationship between diaphragmatic features and physical performance in regular smokers.

Methods

Asymptomatic regular smoker ( n = 22) and nonsmoker ( n = 22) young male subjects (21.63 ± 2.37 years) were participated to the study. The diaphragmatic ultrasonic scanning and physical performance tests of core muscle strength and endurance & Y balance test were performed.

Results

The duration of prone and lateral side bridge ( t = −3.347, t = 3.477, p < 0.001), and modify push‐up test repetition ( Z = −2.213, p = 0.027) were detected lower in regular smokers. A positive moderate correlation was observed between the duration of the prone bridge test and the maximum inspiration thickness & the thickness difference at inspiration and expiration ( r = 0.545, p = 0.009 & r = 0.468, p = 0.028) and between the number of repetitions of the modify push‐up and the maximum expiration thickness ( r = 0.530, p = 0.011).

Conclusion

While no difference was detected in terms of the diaphragm structure between groups, trunk stabilizer performance was lower and greater diaphragm thickness was associated with better trunk stability in some performance tasks in smokers. While the diaphragm muscle structure, which is the main respiratory muscle, does not differ in young smokers, the effects of the diaphragm muscle on general body biomechanics have been preliminary demonstrated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DiaphragmSmokersNon-SmokersMuscle StrengthSmokingHumansMalePilot ProjectsYoung AdultUltrasonographyAdultPostural BalancePhysical Endurance

Stichwörter der Autor:innen

core stabilitydiaphragmposture balancesmokingultrasonographic imaging

Autor:innen und Institutionen

  • Marmara University Health Sciences Faculty Physiotherapy and Rehabilitation Department, Istanbul, Turkey.

Förderung

  • Marmara Üniversitesi

Zitieren

APA

Özgül, B., Sarı, Z., Demirbüken, İ., Can, H. B., Gezer, Z., Yıldırım, H., & Polat, M. G. (2025). Diaphragm thickness and physical performance in regular smokers and non‐smokers: A pilot study. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70003

Vancouver

Özgül B, Sarı Z, Demirbüken İ, Can HB, Gezer Z, Yıldırım H, et al. Diaphragm thickness and physical performance in regular smokers and non‐smokers: A pilot study. Clinical Physiology and Functional Imaging. 2025. doi:10.1111/cpf.70003

BibTeX
@article{zgl2025,
  author = {Özgül, Bahar and Sarı, Zübeyir and Demirbüken, İlkşan and Can, Hilal Başak and Gezer, Zana and Yıldırım, Halil and Polat, Mine Gülden},
  title = {Diaphragm thickness and physical performance in regular smokers and non‐smokers: A pilot study},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2025},
  doi = {10.1111/cpf.70003}
}
Kostenlos starten →