Within‐session repeatability of Doppler ultrasound leg blood flow assessments during exercise in patients with chronic obstructive pulmonary disease
Clinical Physiology and Functional Imaging · 2025
DOI: 10.1111/cpf.12919 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, 2025. Verfasst von Milan Mohammad und 1 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Pulmonary Disease, Chronic Obstructive, Regional Blood Flow, Ultrasonography, Doppler. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Beckett-Fonden, P. Carl Petersens Fond.
Themen: COPD
Abstract (Originalsprache)
Doppler ultrasound can be used to evaluate leg blood flow (Q̇ leg ), especially of interest when investigating peripheral vascular limitations in patients with chronic obstructive pulmonary disease (COPD). However, the within‐session repeatability, a subdomain of test‐retest reliability, of this method remains unknown. This study aimed to provide within‐session repeatability estimates of Doppler ultrasound‐based Q̇ leg at rest and during single‐leg knee‐extensor exercise (KEE) in patients with COPD, and to compare these estimates to matched healthy controls. In this case‐controlled study, 16 participants with COPD were matched based on sex and age with 16 healthy controls. All participants underwent measurement of Q̇ leg using Doppler ultrasound in a KEE setup at various intensities with the same measurement being performed again separated by 10 s. Smallest real difference (SRD) was lowest at rest in both groups and increased during exercise, reaching values ranging from 164 to 231 mL in COPD and 122–180 mL in the control group. The coefficient of variance (CV) was highest at rest and decreased during exercise to values ranging from 4.0% to 5.0% in COPD and 2.6%–3.2% in the control group. The CV was significantly lower in the control group during 0 watt and exercise at 20% of max watt, but apart from that, no reliability estimates were different between groups. To conclude, Doppler ultrasound showed nearly equal within‐session repeatability when evaluating Q̇ leg in COPD patients and healthy individuals with a CV not exceeding 5% during exercise for both groups.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
Förderung
- Beckett-Fonden
- P. Carl Petersens Fond
Zitieren
APA
Mohammad, M., & Hartmann, J. P. (2025). Within‐session repeatability of Doppler ultrasound leg blood flow assessments during exercise in patients with chronic obstructive pulmonary disease. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12919
Vancouver
Mohammad M, Hartmann JP. Within‐session repeatability of Doppler ultrasound leg blood flow assessments during exercise in patients with chronic obstructive pulmonary disease. Clinical Physiology and Functional Imaging. 2025. doi:10.1111/cpf.12919
BibTeX
@article{Mohammad2025,
author = {Mohammad, Milan and Hartmann, Jacob P},
title = {Within‐session repeatability of Doppler ultrasound leg blood flow assessments during exercise in patients with chronic obstructive pulmonary disease},
journal = {Clinical Physiology and Functional Imaging},
year = {2025},
doi = {10.1111/cpf.12919}
}
EUVIMED