EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter‐rater and intra‐rater reliability of multi‐slice CT and three‐dimensional reconstructed imaging analysis of mesenteric vascular anatomy for planning and performing complete mesocolic excision

Jordan Fletcher iD, Phillip Lung, Ellen Van Eetvelde, Claus Anders Bertelsen iD, Adam Stearns iD, Kristian Storli, Danilo Miskovic

Colorectal Disease · 2025-03 · 27 (3)

DOI: 10.1111/codi.70025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Colorectal Disease, online erschienen am 13.03.2025. Verfasst von Jordan Fletcher und 6 weiteren Autor:innen. Beteiligte Einrichtung: St Mark's Hospital and Academic Institute, Harrow, Middlesex, UK. Hauptthemen laut MEDLINE: Mesocolon, Imaging, Three-Dimensional, Colonic Neoplasms, Multidetector Computed Tomography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Complete mesocolic excision (CME) for colon cancer has been associated with improved oncological outcomes but requires a detailed understanding of complex mesenteric vasculature. Three‐dimensional (3D) reconstructed models derived from patient imaging could enhance preoperative anatomical comprehension, enabling safer, precision CME.

Methods

In this two‐phase, blinded, crossover study, four expert CME surgeons evaluated mesenteric vascular anatomy on CT scans and 3D models. In phase 1, surgeons assessed 66 cases, while 20 were re‐evaluated in phase 2. The primary outcome measure was inter‐rater reliability by Fleiss's kappa. Secondary outcomes were intra‐rater reliability by Cohen's kappa and anatomical accuracy rates measured as a percentage of correct responses on a standardised questionnaire.

Results

In phase 1, inter‐rater agreement was higher for 3D models (average kappa 0.6, moderate agreement) than for CT scans (average kappa 0.1, poor agreement). Ileocolic vein drainage and ileocolic artery trajectory showed the highest kappa values with 3D imaging (0.85 and 0.93, respectively). Accuracy was also superior with 3D across all surgeons (mean 89.7% correct) versus CT (mean 79.1% correct, P < 0.001). In phase 2, intra‐rater reliability remained higher for 3D (average Cohen's kappa 0.61) than CT scans (Cohen's kappa 0.27).

Conclusion

3D mesenteric models significantly improve inter‐ and intra‐rater reliability among CME experts over traditional CT scans while markedly enhancing anatomical comprehension accuracy about critical right‐sided colonic vasculature. 3D planning could facilitate CME by enabling superior preoperative visualisation of these vessels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MesocolonImaging, Three-DimensionalColonic NeoplasmsMultidetector Computed TomographyColectomyMesenteric VeinsTomography, X-Ray ComputedMesenteric ArteriesMesenteryHumansReproducibility of ResultsObserver VariationMaleFemaleCross-Over StudiesMiddle AgedAged

Stichwörter der Autor:innen

3DCMEcancercolonimagingplanning

Autor:innen und Institutionen

  • St Mark's Hospital and Academic Institute, Harrow, Middlesex, UK.
  • Department of Surgery and Cancer, Imperial College London, London, UK.
  • Department of Surgery, University Hospital UZ Brussel, Jette, Belgium.
  • Department of Surgery, Copenhagen University Hospital - North Zealand, Hillerød, Denmark.
  • Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Department of Surgery, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK.

ORCID-Profile: Jordan Fletcher, Claus Anders Bertelsen, Adam Stearns

Zitieren

APA

Fletcher, J., Lung, P., Van Eetvelde, E., Bertelsen, C. A., Stearns, A., Storli, K., & Miskovic, D. (2025). Inter‐rater and intra‐rater reliability of multi‐slice CT and three‐dimensional reconstructed imaging analysis of mesenteric vascular anatomy for planning and performing complete mesocolic excision. Colorectal Disease, 27(3). https://doi.org/10.1111/codi.70025

Vancouver

Fletcher J, Lung P, Van Eetvelde E, Bertelsen CA, Stearns A, Storli K, et al. Inter‐rater and intra‐rater reliability of multi‐slice CT and three‐dimensional reconstructed imaging analysis of mesenteric vascular anatomy for planning and performing complete mesocolic excision. Colorectal Disease. 2025;27(3). doi:10.1111/codi.70025

BibTeX
@article{Fletcher2025,
  author = {Fletcher, Jordan and Lung, Phillip and Van Eetvelde, Ellen and Bertelsen, Claus Anders and Stearns, Adam and Storli, Kristian and Miskovic, Danilo},
  title = {Inter‐rater and intra‐rater reliability of multi‐slice CT and three‐dimensional reconstructed imaging analysis of mesenteric vascular anatomy for planning and performing complete mesocolic excision},
  journal = {Colorectal Disease},
  year = {2025},
  volume = {27},
  number = {3},
  doi = {10.1111/codi.70025}
}
Kostenlos starten →