EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Diagnostic Accuracy and Optimal Thresholds of Salivary Pepsin (Peptest) in Laryngopharyngeal Reflux: A Systematic Review and Meta‐Analysis

Do Hyun Kim iD, David W Jang iD, Se Hwan Hwang iD

Clinical Otolaryngology · 2026

DOI: 10.1111/coa.70154 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Clinical Otolaryngology, 2026. Verfasst von Do Hyun Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic…. Hauptthemen laut MEDLINE: Laryngopharyngeal Reflux, Pepsin A, Saliva. Die Arbeit nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Salivary pepsin has been proposed as a non‐invasive biomarker for diagnosing laryngopharyngeal reflux (LPR); however, its diagnostic utility remains uncertain due to inconsistent findings across studies. This meta‐analysis evaluated the diagnostic accuracy of a rapid lateral flow test (Peptest) compared to the reference standard of multichannel intraluminal impedance‐pH (MII‐pH) monitoring. Design and Setting Systematic review and meta‐analysis of cohort studies.

Participants

Patients with LPR. Main Outcome Measures The primary outcomes were diagnostic odds ratio (DOR), summary receiver operating characteristic curve and area under the curve (AUC).

Results

In total, 11 studies comprising 928 samples were included. The diagnostic performance of salivary pepsin for LPR was analysed at cut‐off values of 16, 45–50 and 100 ng/mL. The pooled DOR and AUC were 3.49 and 0.684 at 16 ng/mL, 6.08 and 0.772 at 45–50 ng/mL and 4.78 and 0.717 at 100 ng/mL, respectively. Multiple‐time sampling significantly improved sensitivity compared to single‐time sampling across all cut‐off values (0.82 vs. 0.33–0.63 at 16 ng/mL; p < 0.0001), although specificity was slightly lower.

Conclusions

The Peptest demonstrates potential as a simple, non‐invasive diagnostic alternative to 24‐h‐MII‐pH monitoring for LPR. Among the evaluated thresholds, a cut‐off of 45–50 ng/mL provided the highest diagnostic accuracy. Collecting multiple saliva samples may further enhance detection sensitivity. However, in patients with a high clinical suspicion of LPR but negative Peptest results, 24‐h‐MII‐pH monitoring remains necessary to confirm the diagnosis due to the test's limited negative predictive value.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laryngopharyngeal RefluxPepsin ASalivaHumansBiomarkersEsophageal pH MonitoringSensitivity and Specificity

Stichwörter der Autor:innen

Peptestdiagnosislaryngopharyngeal refluxmeta‐analysispepsinsaliva

Substanzen

BiomarkersPepsin A

Autor:innen und Institutionen

  • Department of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Head and Neck Surgery & Communication Sciences, Duke University School of Medicine, Durham, North Carolina, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

ORCID-Profile: Do Hyun Kim, David W Jang, Se Hwan Hwang

Zitieren

APA

Kim, D. H., Jang, D. W., & Hwang, S. H. (2026). Diagnostic Accuracy and Optimal Thresholds of Salivary Pepsin (Peptest) in Laryngopharyngeal Reflux: A Systematic Review and Meta‐Analysis. Clinical Otolaryngology. https://doi.org/10.1111/coa.70154

Vancouver

Kim DH, Jang DW, Hwang SH. Diagnostic Accuracy and Optimal Thresholds of Salivary Pepsin (Peptest) in Laryngopharyngeal Reflux: A Systematic Review and Meta‐Analysis. Clinical Otolaryngology. 2026. doi:10.1111/coa.70154

BibTeX
@article{Kim2026,
  author = {Kim, Do Hyun and Jang, David W and Hwang, Se Hwan},
  title = {Diagnostic Accuracy and Optimal Thresholds of Salivary Pepsin (Peptest) in Laryngopharyngeal Reflux: A Systematic Review and Meta‐Analysis},
  journal = {Clinical Otolaryngology},
  year = {2026},
  doi = {10.1111/coa.70154}
}
Kostenlos starten →