EUVIMEDEUVIMED entdecken
Crossref

Modification of McGill Oximetry Score in Improving the Diagnostic Capability of Paediatric OSA

Wannitta E Ting Wong, Jeyasakthy Saniasiaya iD, Nur Syazwani Mohd Salehuddin, Shih Ying H'ng, Anna Marie Nathan

Clinical Otolaryngology · 2024-11 · 49 (6) · 801-809

DOI: 10.1111/coa.14214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Otolaryngology, online erschienen am 22.08.2024. Verfasst von Wannitta E Ting Wong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Oximetry, Polysomnography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 59 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to devise a modified oximetry scoring system and calculate its diagnostic accuracy in detecting paediatric obstructive sleep apnoea syndrome (OSAS). Study Design This prospective diagnostic accuracy study was divided into two phases.

Setting

The study was conducted at a quaternary teaching hospital.

Methods

Polysomnograms performed from 1 April 2014 to 31 December 2021 were included. In Phase 1, the parameters of 95 oximetry trend graphs were evaluated, and a modified scoring system was constructed. In Phase 2, the modified scoring system was employed in 272 oximetry trend graphs, and its diagnostic accuracy was determined. A logistic regression model was used to assess the ability of each scoring system to predict paediatric OSAS.

Results

A total of 367 patients were recruited. In Phase 1, a four‐tier severity classification system was constructed. In Phase 2, its diagnostic accuracy was found to be 53.3% sensitive, 97% specific, with positive predictive value of 98.5% and negative predictive value of 34.6%. The lowest detectable apnoea–hypopnoea index (AHI) was 4.5. The inter‐rater reliability calculated was 80%. Logistic regression was applied to assess associations of the modified McGill score (MMS) or McGill oximetry score (MOS) with OSAS. The area under the receiver operating characteristic curve was higher for the MMS than for MOS (0.78 [95% CI 0.73–0.84] vs. 0.59 [95% CI 0.51–0.66]).

Conclusion

This study demonstrated that our modified scoring system had increased sensitivity at detecting OSAS at a much lower AHI and showed a much greater ability to predict paediatric OSAS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea, ObstructiveOximetryPolysomnographyHumansMaleProspective StudiesFemaleChildChild, PreschoolReproducibility of ResultsSeverity of Illness IndexAdolescentPredictive Value of Tests

Stichwörter der Autor:innen

obstructive sleep apnoeapaediatricpulse oximetrysensitivityspecificity

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department of Otorhinolaryngology, Hospital Sultan Idris Shah, Serdang, Malaysia.
  • Department of Pediatrics, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.

ORCID-Profile: Jeyasakthy Saniasiaya

Zitieren

APA

Wong, W. E. T., Saniasiaya, J., Salehuddin, N. S. M., H'ng, S. Y., & Nathan, A. M. (2024). Modification of McGill Oximetry Score in Improving the Diagnostic Capability of Paediatric OSA. Clinical Otolaryngology, 49(6), 801-809. https://doi.org/10.1111/coa.14214

Vancouver

Wong WET, Saniasiaya J, Salehuddin NSM, H'ng SY, Nathan AM. Modification of McGill Oximetry Score in Improving the Diagnostic Capability of Paediatric OSA. Clinical Otolaryngology. 2024;49(6):801-809. doi:10.1111/coa.14214

BibTeX
@article{Wong2024,
  author = {Wong, Wannitta E Ting and Saniasiaya, Jeyasakthy and Salehuddin, Nur Syazwani Mohd and H'ng, Shih Ying and Nathan, Anna Marie},
  title = {Modification of McGill Oximetry Score in Improving the Diagnostic Capability of Paediatric OSA},
  journal = {Clinical Otolaryngology},
  year = {2024},
  volume = {49},
  number = {6},
  pages = {801--809},
  doi = {10.1111/coa.14214}
}
Kostenlos starten →