Feasibility and effectiveness of transcutaneous auricular vagus nerve stimulation ( taVNS ) in awake mice
CNS Neuroscience & Therapeutics · 2024-09 · 30 (9)
DOI: 10.1111/cns.70043 ↗Kurz gefasst
Fachartikel in der Zeitschrift CNS Neuroscience & Therapeutics, online erschienen am 11.09.2024. Verfasst von Yu-Mei Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Jiangsu Province Key Laboratory of Anesthesiology, Xuzhou Medical University, Xuzhou, Jiangsu, China. Hauptthemen laut MEDLINE: Vagus Nerve Stimulation, Wakefulness, Transcutaneous Electric Nerve Stimulation, Feasibility Studies. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Aims
Transcutaneous auricular vagus nerve stimulation (taVNS) is widely used to treat a variety of disorders because it is noninvasive, safe, and well tolerated by awake patients. However, long‐term and repetitive taVNS is difficult to achieve in awake mice. Therefore, developing a new taVNS method that fully mimics the method used in clinical settings and is well‐tolerated by awake mice is greatly important for generalizing research findings related to the effects of taVNS. The study aimed to develop a new taVNS device for use in awake mice and to test its reliability and effectiveness.
Methods
We demonstrated the reliability of this taVNS device through retrograde neurotropic pseudorabies virus (PRV) tracing and evaluated its effectiveness through morphological analysis. After 3 weeks of taVNS application, the open field test (OFT) and elevated plus maze (EPM) were used to evaluate anxiety‐like behaviors, and the Y‐maze test and novel object recognition test (NORT) were used to evaluate recognition memory behaviors, respectively.
Results
We found that repetitive taVNS was well tolerated by awake mice, had no effect on anxiety‐like behaviors, and significantly improved memory.
Conclusion
Our findings suggest that this new taVNS device for repetitive stimulation of awake mice is safe, tolerable, and effective.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Jiangsu Province Key Laboratory of Anesthesiology, Xuzhou Medical University, Xuzhou, Jiangsu, China.
- Jiangsu Province Key Laboratory of Anesthesia and Analgesia Application Technology, Xuzhou Medical University, Xuzhou, Jiangsu, China.
- NMPA Key Laboratory for Research and Evaluation of Narcotic and Psychotropic Drugs, Xuzhou Medical University, Xuzhou, Jiangsu, China.
- Department of Anesthesiology, Xuzhou First People's Hospital, Xuzhou, Jiangsu, China.
- Department of Anesthesiology, Xuzhou Central Hospital, Xuzhou, Jiangsu, China.
- Department of Anesthesiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
ORCID-Profile: Yang-Zi Zhu, Jun-Li Cao
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Yu, Y. M., Yao, R., Liu, Z. L., Lu, Y., Zhu, Y. Z., & Cao, J. L. (2024). Feasibility and effectiveness of transcutaneous auricular vagus nerve stimulation ( taVNS ) in awake mice. CNS Neuroscience & Therapeutics, 30(9). https://doi.org/10.1111/cns.70043
Vancouver
Yu YM, Yao R, Liu ZL, Lu Y, Zhu YZ, Cao JL. Feasibility and effectiveness of transcutaneous auricular vagus nerve stimulation ( taVNS ) in awake mice. CNS Neuroscience & Therapeutics. 2024;30(9). doi:10.1111/cns.70043
BibTeX
@article{Yu2024,
author = {Yu, Yu-Mei and Yao, Rui and Liu, Zhou-Liang and Lu, Yao and Zhu, Yang-Zi and Cao, Jun-Li},
title = {Feasibility and effectiveness of transcutaneous auricular vagus nerve stimulation ( taVNS ) in awake mice},
journal = {CNS Neuroscience & Therapeutics},
year = {2024},
volume = {30},
number = {9},
doi = {10.1111/cns.70043}
}