AI Enabled Automated Digital Image Analysis for Peri‐Implant Health Monitoring: A Preliminary Diagnostic Study
Clinical Oral Implants Research · 01.11.2026
DOI: 10.1111/clr.70200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 01.11.2026. Verfasst von Xinyu Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Implantology, Shanghai Ninth People Hospital, Shanghai Jiao Tong University School of Medicine, College of Stoma…. Die Arbeit nennt 18 Literaturangaben. Gefördert von: the Postdoctoral Start-up Grant of Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine.
Abstract (Originalsprache)
Objectives
To develop and validate an AI‐driven Digital Erythema Score (DES) for objective, non‐invasive assessment of peri‐implant mucosal erythema using intraoral scan (IOS) data. Materials and Methods An internal dataset (200 patients, 265 implants) was utilized, with the reference standard established via consensus by two independent experts. We developed a U‐Net model to automatically segment the peri‐implant mucosal margins to calculate the DES and diagnose erythema (modified Gingival Index mGI 0, ≥ 1). We used the YOLO model for object detection to localize erythema regions. The system's diagnostic performance was validated on an independent external dataset (23 patients, 30 implants), supplemented by a multi‐observer study to evaluate the AI's assistance across clinicians with varying experience levels.
Results
The U‐Net model achieved precise ROI segmentation (Dice similarity coefficient 0.69 ± 0.11) and reliable colorimetric calculation (ICC > 0.95). At the optimal threshold, the DES accurately identified mucosal erythema (AUC, internal 0.9228 [95% CI: 0.8533 to 0.9760], external 0.9018 [0.8135 to 0.9773]). DES and mGI showed significant correlations with bleeding on probing ( B = 7.38, OR = 5.32, both p < 0.001 ). The YOLO model localized inflammatory regions (mAP internal 0.8968, external 0.6820). In the external validation, the DES‐driven diagnostic framework enhanced the diagnostic performance of observers with different levels of experience and increased the inter‐observer consistency.
Conclusions
The DES provides an objective metric that converts chromatic signals into a diagnostic score and is significantly correlated with clinical inflammation. This AI‐driven framework reduces clinical subjectivity and establishes a non‐invasive paradigm for teledentistry and high‐frequency, home‐based monitoring of peri‐implant health in the future after validation with patient‐accessible imaging devices. Trial Registration This study has been prospectively registered (NCT07349095)
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Implantology, Shanghai Ninth People Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center of Stomatology,…
ORCID-Profile: Xinyu Wu, Xindi Wei, Xiaolei Lv, Xiaojiao Fu, Hongchang Lai, Junyu Shi
Förderung
- the Postdoctoral Start-up Grant of Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
Zitieren
APA
Wu, X., Wei, X., Lv, X., Fu, X., He, Z., Yin, W., Lai, H., & Shi, J. (2026). AI Enabled Automated Digital Image Analysis for Peri‐Implant Health Monitoring: A Preliminary Diagnostic Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70200
Vancouver
Wu X, Wei X, Lv X, Fu X, He Z, Yin W, et al. AI Enabled Automated Digital Image Analysis for Peri‐Implant Health Monitoring: A Preliminary Diagnostic Study. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70200
BibTeX
@article{Wu2026,
author = {Wu, Xinyu and Wei, Xindi and Lv, Xiaolei and Fu, Xiaojiao and He, Ziqi and Yin, Wanting and Lai, Hongchang and Shi, Junyu},
title = {AI Enabled Automated Digital Image Analysis for Peri‐Implant Health Monitoring: A Preliminary Diagnostic Study},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70200}
}
EUVIMED