Digitally Guided Hydraulic Crestal Sinus Floor Elevation Versus Free‐Hand Osteotome Technique: A Single‐Blinded Randomized Controlled Clinical Trial
Clinical Oral Implants Research · 2026
DOI: 10.1111/clr.70062 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, 2026. Verfasst von Mahsa Enssi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran. Hauptthemen laut MEDLINE: Sinus Floor Augmentation, Osteotomy, Surgery, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To compare the clinical and radiographic outcomes of crestal sinus floor elevation (SFE) using a digital surgical guide (DSG) and hydraulic sinus lift technique versus the conventional osteotome technique.
Methods
Patients requiring crestal SFE and single‐implant placement in the posterior maxilla with a minimum of 5 mm of residual bone height were included and randomly assigned to two groups of crestal SFE with (i) the conventional technique (elevation of a mucoperiosteal flap and SFE by the osteotome technique, control group) and (ii) by using a DSG (without flap elevation, by using the sinus lift hydraulic system in the presence of a DSG, test group). Frequency of intraoperative membrane perforation, surgical time, and patient‐reported outcomes were collected. Crestal bone loss at 6 months, new bone formation in the sinus, and implant position were assessed.
Results
Twenty‐three patients (24 implants, 12 in each group) were included. The DSG group experienced significantly lower postoperative pain (measured by the number of analgesics taken, 1.67 ± 0.77 vs. 2.75 ± 1.21, p = 0.028), shorter surgical time (22.3 ± 2.4 vs. 33.1 ± 4.1 min, p < 0.001), and smaller deviation of implant angulation from the ideal position (2.9° ± 0.6° vs. 8.6° ± 1.3°, p < 0.001) compared to the conventional group. The difference in other parameters was not significant.
Conclusion
Considering the study limitations, using a DSG with a hydraulic system for crestal SFE was superior to the conventional technique regarding pain score, surgical time, and implant angulation. Due to the relatively small sample size and lack of statistically significant differences in some parameters, these findings should be interpreted with caution. Trial Registration Iranian Registry of Clinical Trials: IRCT20230529058333N1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Periodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran.
- Department of Radiology, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran.
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.
ORCID-Profile: Hamoun Sabri
Zitieren
APA
Enssi, M., Karimi, M., Etemadi, A., Khademi, M., & Sabri, H. (2026). Digitally Guided Hydraulic Crestal Sinus Floor Elevation Versus Free‐Hand Osteotome Technique: A Single‐Blinded Randomized Controlled Clinical Trial. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70062
Vancouver
Enssi M, Karimi M, Etemadi A, Khademi M, Sabri H. Digitally Guided Hydraulic Crestal Sinus Floor Elevation Versus Free‐Hand Osteotome Technique: A Single‐Blinded Randomized Controlled Clinical Trial. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70062
BibTeX
@article{Enssi2026,
author = {Enssi, Mahsa and Karimi, Mohammadreza and Etemadi, Ardavan and Khademi, Mahsa and Sabri, Hamoun},
title = {Digitally Guided Hydraulic Crestal Sinus Floor Elevation Versus Free‐Hand Osteotome Technique: A Single‐Blinded Randomized Controlled Clinical Trial},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70062}
}
EUVIMED