Artificial Intelligence in Detecting and Segmenting Vertical Misfit of Prosthesis in Radiographic Images of Dental Implants: A Cross‐Sectional Analysis
Clinical Oral Implants Research · 2025
DOI: 10.1111/clr.14406 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Paniz Fasih und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran. Hauptthemen laut MEDLINE: Artificial Intelligence, Dental Implants, Crowns, Radiography, Dental. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Objective
This study evaluated ResNet‐50 and U‐Net models for detecting and segmenting vertical misfit in dental implant crowns using periapical radiographic images.
Methods
Periapical radiographs of dental implant crowns were classified by two experts based on the presence of vertical misfit (reference group). The misfit area was manually annotated in images exhibiting vertical misfit. The resulting datasets were utilized to train the ResNet‐50 and U‐Net deep learning models. Then, 70% of the images were allocated for training, while the remaining 30% were used for validation and testing. Five general dentists categorized the testing images as “misfit” or “fit.” Inter‐rater reliability with Cohen's kappa index and performance metrics were calculated. The average performance metrics of dentists and artificial intelligence (AI) were compared using the paired‐samples t test.
Results
A total of 638 radiographs were collected. The kappa values between dentists and AI ranged from 0.93 to 0.98, indicating perfect agreement. The ResNet‐50 model achieved accuracy and precision of 92.7% and 87.5%, respectively, whereas dentists had a mean accuracy of 93.3% and precision of 89.6%. The sensitivity and specificity for AI were 90.3% and 93.8%, respectively, compared to 90.1% and 95.1% for dentists. The Dice coefficient yielded 88.9% for the ResNet‐50 and 89.5% among the dentists. The U‐Net algorithm produced a loss of 0.01 and an accuracy of 0.98. No significant difference was found between the average performance metrics of dentists and AI ( p > 0.05).
Conclusion
AI can detect and segment vertical misfit of implant prosthetic crowns in periapical radiographs, comparable to clinician performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran.
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran.
- Oral and Maxillofacial Surgeon, Tehran, Iran.
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran.
ORCID-Profile: Paniz Fasih, Amir Yari, Lotfollah Kamali Hakim
Zitieren
APA
Fasih, P., Yari, A., Kamali Hakim, L., & Kashe, N. N. (2025). Artificial Intelligence in Detecting and Segmenting Vertical Misfit of Prosthesis in Radiographic Images of Dental Implants: A Cross‐Sectional Analysis. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14406
Vancouver
Fasih P, Yari A, Kamali Hakim L, Kashe NN. Artificial Intelligence in Detecting and Segmenting Vertical Misfit of Prosthesis in Radiographic Images of Dental Implants: A Cross‐Sectional Analysis. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14406
BibTeX
@article{Fasih2025,
author = {Fasih, Paniz and Yari, Amir and Kamali Hakim, Lotfollah and Kashe, Nader Nasim},
title = {Artificial Intelligence in Detecting and Segmenting Vertical Misfit of Prosthesis in Radiographic Images of Dental Implants: A Cross‐Sectional Analysis},
journal = {Clinical Oral Implants Research},
year = {2025},
doi = {10.1111/clr.14406}
}
EUVIMED