EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparing the modified socket‐shield technique with the conventional immediate implantation technique in the anterior dentition: A 5‐year retrospective clinical study

Xingfu Li, Xinhan Li, Yamei Xu, Gang Fu iD, Hong Huang iD

Clinical Oral Implants Research · 2024

DOI: 10.1111/clr.14281 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Xingfu Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Stomatology, Chongqing Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Immediate Dental Implant Loading. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Science-Health Joint Medical Scientific Research Project of Chongqing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The aim of this retrospective clinical study was to compare the 5‐year radiological and clinical outcomes of patients undergoing immediate implantation with or without the modified socket‐shield technique. Materials and Methods Patients who underwent anterior tooth replacement via the modified socket‐shield technique (MSST) or the conventional immediate implantation technique (CIIT) between 2016 and 2017 were included. The labial bone thickness was assessed at different measurement levels (0, 2, 4 and 6 mm apical to the implant shoulder (IS)) postoperatively (T1), 6 months postoperatively (T2) and 5 years postoperatively (T3). The pink aesthetic score (PES) was evaluated before surgery (T0) and at T2 and T3. Implant success, complications and patient satisfaction were evaluated at every visit.

Results

Thirty‐six patients (18 in the MSST group) underwent follow‐up for 5 years, with no cases of implant failure. Two cases of exposure were detected in the MSST group, but there were no significant effects on hard or soft tissue. Patients in the MSST group showed less and more stable bone resorption than did those in the CIIT group at any measurement level and any time. A higher PES was achieved in the MSST group. Patient satisfaction was similar in both groups.

Conclusions

The MSST is a reliable immediate implantation method because of its ability to preserve the alveolar bone and provide superior recovery of aesthetics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Immediate Dental Implant LoadingHumansRetrospective StudiesMaleFemaleAdultMiddle AgedTooth SocketPatient SatisfactionEsthetics, DentalDental Implantation, EndosseousTreatment Outcome

Stichwörter der Autor:innen

aestheticsanteriorbone resorptionconventional immediate implantation techniquelabial bone platemodified socket‐shield technique

Autor:innen und Institutionen

  • College of Stomatology, Chongqing Medical University, Chongqing, China.
  • Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China.
  • Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.

ORCID-Profile: Gang Fu, Hong Huang

Förderung

  • Science-Health Joint Medical Scientific Research Project of Chongqing

Zitieren

APA

Li, X., Li, X., Xu, Y., Fu, G., & Huang, H. (2024). Comparing the modified socket‐shield technique with the conventional immediate implantation technique in the anterior dentition: A 5‐year retrospective clinical study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14281

Vancouver

Li X, Li X, Xu Y, Fu G, Huang H. Comparing the modified socket‐shield technique with the conventional immediate implantation technique in the anterior dentition: A 5‐year retrospective clinical study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14281

BibTeX
@article{Li2024,
  author = {Li, Xingfu and Li, Xinhan and Xu, Yamei and Fu, Gang and Huang, Hong},
  title = {Comparing the modified socket‐shield technique with the conventional immediate implantation technique in the anterior dentition: A 5‐year retrospective clinical study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  doi = {10.1111/clr.14281}
}
Kostenlos starten →