EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Comparing Accuracy of Cylindrical and Tapered Implants Using Autonomous Robotic System: A Randomized Controlled Trial

Miaomiao Tian iD, Zhiyuan Shu iD, Shanshan Shi iD, Hongbo Wei iD

Clinical Implant Dentistry and Related Research · 2026-06 · 28 (3)

DOI: 10.1111/cid.70159 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 12.05.2026. Verfasst von Miaomiao Tian und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Clinical Research Center for Oral Diseases, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Shaanxi Clinical R…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Dental Prosthesis Design, Robotic Surgical Procedures, Robotics. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Fourth Military Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to systematically evaluate the effect of implant shape (cylindrical versus tapered implant) on the accuracy of placement using an autonomous robotic system in patients with single‐tooth loss. Materials and Methods Forty individuals with a single missing tooth were randomly assigned to receive either a cylindrical implant (CI) or a tapered implant (TI). All implants were digitally planned and placed with an autonomous robotic system. The primary outcomes were coronal, apical, and angular deviations. Secondary outcomes included surgery time and insertion torque value (ITV).

Results

A significantly smaller apical deviation was observed in the TI group (0.70 ± 0.23 mm) compared to the CI group (0.91 ± 0.38 mm; p < 0.05), and there was statistically smaller angular deviation in the TI group (1.18° ± 0.46°) than the CI group (1.76° ± 1.02°; p < 0.05). Furthermore, the implantation time was also significantly shorter in the TI group (5.88 ± 2.34 min) than the CI group (9.84 ± 5.45 min; p < 0.01), and the TI group (24.33 ± 11.47 N cm) was statistically lower than the CI group (31.75 ± 10.17 N cm; p < 0.05) in ITV. No statistically significant differences were observed regarding coronal deviation and osteotomy duration between the two groups.

Conclusions

Considering the study's limitations, both implant shapes were automatically placed with clinically acceptable accuracy. Tapered implants, however, demonstrated statistically superior apical and angular positioning accuracy and a more efficient insertion process without compromising primary stability. These findings warrant further investigation to confirm their clinical relevance. Trail Registration: ChiCTR2500105588.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousDental Prosthesis DesignRobotic Surgical ProceduresRoboticsDental Implants, Single-ToothDental ImplantsHumansAutonomous RobotsFemaleTorqueMiddle AgedAdult

Stichwörter der Autor:innen

autonomous robotic systemdental implantimplant shaperandomized controlled trial

Substanzen

Dental Implants

Autor:innen und Institutionen

  • National Clinical Research Center for Oral Diseases, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Shaanxi Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center…

ORCID-Profile: Miaomiao Tian, Zhiyuan Shu, Shanshan Shi, Hongbo Wei

Förderung

  • Fourth Military Medical University

Zitieren

APA

Tian, M., Shu, Z., Shi, S., & Wei, H. (2026). Comparing Accuracy of Cylindrical and Tapered Implants Using Autonomous Robotic System: A Randomized Controlled Trial. Clinical Implant Dentistry and Related Research, 28(3). https://doi.org/10.1111/cid.70159

Vancouver

Tian M, Shu Z, Shi S, Wei H. Comparing Accuracy of Cylindrical and Tapered Implants Using Autonomous Robotic System: A Randomized Controlled Trial. Clinical Implant Dentistry and Related Research. 2026;28(3). doi:10.1111/cid.70159

BibTeX
@article{Tian2026,
  author = {Tian, Miaomiao and Shu, Zhiyuan and Shi, Shanshan and Wei, Hongbo},
  title = {Comparing Accuracy of Cylindrical and Tapered Implants Using Autonomous Robotic System: A Randomized Controlled Trial},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2026},
  volume = {28},
  number = {3},
  doi = {10.1111/cid.70159}
}
Kostenlos starten →