EUVIMEDEUVIMED entdecken
Crossref

Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study

Liangfu Huang, Huiyu Yao, YanBin Sun, Qingyu Yu, Jiayan Li, Xi Ding iD, Jianjing Huang iD

Clinical Implant Dentistry and Related Research · 2026

DOI: 10.1111/cid.70133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2026. Verfasst von Liangfu Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, West Branch of Hangzhou Stomatology Hospital, Hangzhou, Zhejiang, China. Hauptthemen laut MEDLINE: Dental Occlusion, Dental Prosthesis, Implant-Supported, Mandible, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Zhejiang Provincial Medical and Health Science and Technology Plan, Wenzhou Major Scientific and Technological Innovation Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the clinical efficacy of prostheses designed using mandibular motion analysis in maxillary full‐arch implant rehabilitation.

Methods

Twenty patients were assigned to a study group ( n = 10), receiving prostheses designed with dynamic occlusal data from an electronic jaw motion analyzer ( JMA ), or a control group ( n = 10) using conventional static digital workflows. Between‐group differences in occlusal adjustment depth ( MAE ), area, and chairside time were analyzed by independent t‐tests. Within the study group, the stability of mandibular movement paths (provisional vs. post‐restoration) was assessed using paired t‐tests. Oral health‐related quality of life ( OHRQoL ) was evaluated using the OHIP‐14 questionnaire. Effect sizes were calculated as Hedges’ g .

Results

The study group exhibited significantly lower occlusal adjustment depth (163.26 ± 31.42 μm vs. 213.99 ± 56.38 μm; p = 0.030, Hedges’ g = 1.06) and adjustment area (95.93 ± 30.27 mm 2 vs. 129.86 ± 25.82 mm 2 ; p = 0.020, g = 1.16) compared to the control group. Chairside adjustment time was reduced by approximately 30% (23.8 ± 7.8 min vs. 33.8 ± 8.0 min; p = 0.074, g = 1.15). No significant changes in parameters of mandibular movement paths were observed within the study group post‐restoration (all p > 0.05). OHIP ‐14 scores were significantly better in the study group for “Meal interruption”, “Relaxation difficulty” ( p = 0.041), reflecting improved OHRQoL .

Conclusion

Integrating dynamic mandibular motion data into prosthesis design reduces clinical adjustments, improves OHRQoL , and preserves inherent movement patterns, demonstrating a promising approach to optimize functional outcomes in full‐arch implant rehabilitation. Clinical Significance Integrating dynamic mandibular motion data into digital prosthesis design offers a clinically valuable strategy that minimizes occlusal adjustments, supports functional stability, and enhances patient‐reported quality of life in full‐arch implant rehabilitation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental OcclusionDental Prosthesis, Implant-SupportedMandibleDental Prosthesis DesignDental ImplantsHumansRetrospective StudiesFemaleMaleMaxillaQuality of LifeMiddle AgedAgedMotion CaptureMovement

Stichwörter der Autor:innen

CAD/CAMdental implantsdynamic guidancemandibular motion analysis systemocclusion

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Stomatology, West Branch of Hangzhou Stomatology Hospital, Hangzhou, Zhejiang, China.
  • Department of Stomatology, Zheyi EENT Hospital, Hangzhou, Zhejiang, China.
  • School of Public Health, Wenzhou Medical University, Wenzhou, Zhejiang, China.
  • Department of Stomatology, The First Affiliated Hospital of Wenzhou, Medical University, Wenzhou, Zhejiang, China.

ORCID-Profile: Xi Ding, Jianjing Huang

Förderung

  • Zhejiang Provincial Medical and Health Science and Technology Plan
  • Wenzhou Major Scientific and Technological Innovation Project

Zitieren

APA

Huang, L., Yao, H., Sun, Y., Yu, Q., Li, J., Ding, X., & Huang, J. (2026). Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70133

Vancouver

Huang L, Yao H, Sun Y, Yu Q, Li J, Ding X, et al. Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study. Clinical Implant Dentistry and Related Research. 2026. doi:10.1111/cid.70133

BibTeX
@article{Huang2026,
  author = {Huang, Liangfu and Yao, Huiyu and Sun, YanBin and Yu, Qingyu and Li, Jiayan and Ding, Xi and Huang, Jianjing},
  title = {Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2026},
  doi = {10.1111/cid.70133}
}
Kostenlos starten →