Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study
Clinical Implant Dentistry and Related Research · 2026
DOI: 10.1111/cid.70133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2026. Verfasst von Liangfu Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, West Branch of Hangzhou Stomatology Hospital, Hangzhou, Zhejiang, China. Hauptthemen laut MEDLINE: Dental Occlusion, Dental Prosthesis, Implant-Supported, Mandible, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Zhejiang Provincial Medical and Health Science and Technology Plan, Wenzhou Major Scientific and Technological Innovation Project.
Abstract (Originalsprache)
Objectives
To evaluate the clinical efficacy of prostheses designed using mandibular motion analysis in maxillary full‐arch implant rehabilitation.
Methods
Twenty patients were assigned to a study group ( n = 10), receiving prostheses designed with dynamic occlusal data from an electronic jaw motion analyzer ( JMA ), or a control group ( n = 10) using conventional static digital workflows. Between‐group differences in occlusal adjustment depth ( MAE ), area, and chairside time were analyzed by independent t‐tests. Within the study group, the stability of mandibular movement paths (provisional vs. post‐restoration) was assessed using paired t‐tests. Oral health‐related quality of life ( OHRQoL ) was evaluated using the OHIP‐14 questionnaire. Effect sizes were calculated as Hedges’ g .
Results
The study group exhibited significantly lower occlusal adjustment depth (163.26 ± 31.42 μm vs. 213.99 ± 56.38 μm; p = 0.030, Hedges’ g = 1.06) and adjustment area (95.93 ± 30.27 mm 2 vs. 129.86 ± 25.82 mm 2 ; p = 0.020, g = 1.16) compared to the control group. Chairside adjustment time was reduced by approximately 30% (23.8 ± 7.8 min vs. 33.8 ± 8.0 min; p = 0.074, g = 1.15). No significant changes in parameters of mandibular movement paths were observed within the study group post‐restoration (all p > 0.05). OHIP ‐14 scores were significantly better in the study group for “Meal interruption”, “Relaxation difficulty” ( p = 0.041), reflecting improved OHRQoL .
Conclusion
Integrating dynamic mandibular motion data into prosthesis design reduces clinical adjustments, improves OHRQoL , and preserves inherent movement patterns, demonstrating a promising approach to optimize functional outcomes in full‐arch implant rehabilitation. Clinical Significance Integrating dynamic mandibular motion data into digital prosthesis design offers a clinically valuable strategy that minimizes occlusal adjustments, supports functional stability, and enhances patient‐reported quality of life in full‐arch implant rehabilitation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Stomatology, West Branch of Hangzhou Stomatology Hospital, Hangzhou, Zhejiang, China.
- Department of Stomatology, Zheyi EENT Hospital, Hangzhou, Zhejiang, China.
- School of Public Health, Wenzhou Medical University, Wenzhou, Zhejiang, China.
- Department of Stomatology, The First Affiliated Hospital of Wenzhou, Medical University, Wenzhou, Zhejiang, China.
ORCID-Profile: Xi Ding, Jianjing Huang
Förderung
- Zhejiang Provincial Medical and Health Science and Technology Plan
- Wenzhou Major Scientific and Technological Innovation Project
Zitieren
APA
Huang, L., Yao, H., Sun, Y., Yu, Q., Li, J., Ding, X., & Huang, J. (2026). Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70133
Vancouver
Huang L, Yao H, Sun Y, Yu Q, Li J, Ding X, et al. Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study. Clinical Implant Dentistry and Related Research. 2026. doi:10.1111/cid.70133
BibTeX
@article{Huang2026,
author = {Huang, Liangfu and Yao, Huiyu and Sun, YanBin and Yu, Qingyu and Li, Jiayan and Ding, Xi and Huang, Jianjing},
title = {Dynamic Occlusal Design Using Jaw Motion Data for Maxillary Full‐Arch Implant Rehabilitation: A Retrospective Study},
journal = {Clinical Implant Dentistry and Related Research},
year = {2026},
doi = {10.1111/cid.70133}
}