EUVIMEDEUVIMED entdecken
Crossref

Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study

ChengI Chu iD, Youming Luo, Xueyuan Li iD, Songhang Li iD

Clinical Implant Dentistry and Related Research · 2025-10 · 27 (5)

DOI: 10.1111/cid.70089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 08.09.2025. Verfasst von ChengI Chu und 3 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Oral Impla…. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Dental Implants. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province, Postdoctoral Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This in vitro study evaluated how different forces applied to the dental drill handle during static computer‐assisted implant surgery influence surgical guide deformation and implant placement accuracy.

Methods

Twenty‐four virtual implants were divided into six groups (0–10 N, in 2 N increments). Surgical guides were scanned under loaded conditions, and deviations were quantified by superimposition with the baseline model.

Results

At high forces (≥ 8 N), buccal and palatal deformations increased markedly, with the 10 N group showing the largest displacement and angular deviation. Apical deviations (up to 1.554 mm) exceeded platform deviations (0.720 mm), and angular changes reached 9.595°. Under low forces (2–4 N), deformations were minimal, and anterior regions showed greater stability than posterior regions.

Conclusion

Forces above 6 N approach or exceed clinically acceptable thresholds, while 0 to 4 N produced the most precise outcomes. A single overload (≥ 8 N) can jeopardize surgical precision and long‐term implant stability, underscoring the importance of controlling drill handle force. Clinicians are therefore advised to limit applied forces to ≤ 4 N to preserve surgical accuracy and minimize guide distortion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousDental ImplantsHumansIn Vitro Techniques

Stichwörter der Autor:innen

3D printingdental implantforcein vitrostatic computer‐assisted implant surgerysurgical guides

Substanzen

Dental Implants

Autor:innen und Institutionen

  • State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Cheng…
  • Department of Ophthalmology, The General Hospital of Western Theater Command, Chengdu, China.

ORCID-Profile: ChengI Chu, Xueyuan Li, Songhang Li

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Sichuan Province
  • Postdoctoral Science Foundation of China
  • Postdoctoral Fellowship Program of CPSF
  • Postdoctoral Foundation of Sichuan University
  • Sichuan University Interdisciplinary Innovation Fund
  • Exploration and R&D Project of West China Hospital of Stomatology

Zitieren

APA

Chu, C., Luo, Y., Li, X., & Li, S. (2025). Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study. Clinical Implant Dentistry and Related Research, 27(5). https://doi.org/10.1111/cid.70089

Vancouver

Chu C, Luo Y, Li X, Li S. Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study. Clinical Implant Dentistry and Related Research. 2025;27(5). doi:10.1111/cid.70089

BibTeX
@article{Chu2025,
  author = {Chu, ChengI and Luo, Youming and Li, Xueyuan and Li, Songhang},
  title = {Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {5},
  doi = {10.1111/cid.70089}
}
Kostenlos starten →