Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 04.04.2025. Verfasst von Stefan Krennmair und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Keplerklinikum Linz, Johannes Kepler University (JKU) Linz, Linz, Austria. Hauptthemen laut MEDLINE: Sinus Floor Augmentation, Maxillary Sinus, Osteogenesis, Bone Substitutes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 62 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The present study aimed to evaluate and to compare the influence of anatomical variables such as sinus width (SW), inner maxillary sinus contour length (IMSCL), and residual ridge height (RRH) on new bone formation (%NBF) for deproteinized porcine (DPBM) and bovine bone mineral (DBBM) used for lateral window sinus augmentation (LWSA) grafting. Material and Methods For LWSA groups grafted either with DPBM ( n = 10) or DBBM ( n = 13) a linear‐ as well as a multivariate‐regression analysis was conducted between measured %NBF and radiographically retrospectively assessed anatomical variables (SW/IMSCL/RRH). Correlations as well as regression coefficients ( R 2 ) were calculated, evaluating the influence of anatomical variables on %NBF with differentiation between both xenogenic graft materials used.

Results

With no differences for patient‐epidemiologic data, for anatomical variables as well as for surgical‐ and patient‐related risk factors, comparison between the two LWSA groups was possible. The linear‐regression analysis provided significant correlations between histomorphometrically evaluated %NBF and SW (DPBM: r = −0.660, p = 0.038; DBBM: r = −0.614, p = 0.026) as well as between %NBF and IMSCL (DPBM: r = −0.737; p = 0.015, DBBM: r = −0.573, p = 0.041), but not for RRH. Between SW/IMSCL/RRH and %NBF, regression‐coefficients‐(R 2 ) of 0.435/0.543/0.258 using DPBM and R 2 of 0.377/0.328/0.053 using DBBM represented evidently higher influences of anatomical structures when porcine graft material was applied. The multivariate‐regression analysis confirmed the different influence between various xenogenic graft materials on % NBF as well with a pronounced effect for porcine material (DPBM: R 2 = 0.591 [59.1%] vs. DBBM: R 2 = 0.314 [31.4%]).

Conclusion

In LWSA, anatomical structures such as SW and IMSCL significantly affect new bone formation, though with varying effects for different xenogenic (porcine vs. bovine) bone mineral graft materials used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sinus Floor AugmentationMaxillary SinusOsteogenesisBone SubstitutesBone TransplantationRetrospective StudiesHumansAnimalsCattleMiddle AgedSwineMaleFemaleAdultAgedMinerals

Stichwörter der Autor:innen

anatomical variablesbone regenerationmaxillary sinus

Substanzen

Bone SubstitutesBio-OssMinerals

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, Keplerklinikum Linz, Johannes Kepler University (JKU) Linz, Linz, Austria.
  • Num-Biolab, Ludwig-Maximilian University (LMU), Munich, Germany.
  • Dental School, Medical University Graz, Austria.
  • Musco-Skeletal Research Unit, Medical University Graz, Austria.
  • Department of Applied Systems and Statistics, Johannes Kepler University Linz (JKU), Linz, Austria.
  • Department of Prosthodontics, Dental School, Sigmund Freud Medical University of Vienna, Johannes Kepler University (JKU), Linz, Austria.

ORCID-Profile: Uwe-Yalcin Schwarze, Thomas Forstner, Gerald Krennmair

Zitieren

APA

Krennmair, S., Weinländer, M., Schwarze, U. Y., Malek, M., Forstner, T., & Krennmair, G. (2025). Varying Influence of Maxillary Sinus Dimensions on New Bone Formation With Various Graft Materials in Lateral Window Sinus Augmentation—A Retrospective Study. Clinical Implant Dentistry and Related Research, 27(2). https://doi.org/10.1111/cid.70014

Vancouver

Krennmair S, Weinländer M, Schwarze UY, Malek M, Forstner T, Krennmair G. Varying Influence of Maxillary Sinus Dimensions on New Bone Formation With Various Graft Materials in Lateral Window Sinus Augmentation—A Retrospective Study. Clinical Implant Dentistry and Related Research. 2025;27(2). doi:10.1111/cid.70014

BibTeX
@article{Krennmair2025,
  author = {Krennmair, Stefan and Weinländer, Michael and Schwarze, Uwe-Yalcin and Malek, Michael and Forstner, Thomas and Krennmair, Gerald},
  title = {Varying Influence of Maxillary Sinus Dimensions on New Bone Formation With Various Graft Materials in Lateral Window Sinus Augmentation—A Retrospective Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {2},
  doi = {10.1111/cid.70014}
}
Kostenlos starten →