EUVIMEDEUVIMED entdecken
Crossref

Accuracy of immediately placed implants using surgical guides from different 3‐dimensional printers: An in vitro study

Jeremy Pitman iD, Jan Cosyn iD, Véronique Christiaens iD, Faris Younes iD, Thomas de Bruyckere iD, Stijn Vervaeke iD, Maarten Glibert iD

Clinical Implant Dentistry and Related Research · 2024-10 · 26 (5) · 922-929

DOI: 10.1111/cid.13354 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 26.06.2024. Verfasst von Jeremy Pitman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology and Oral Implantology, Faculty of Medicine and Health Sciences, Oral Health Sciences, Ghent University, Ghent, Belgium. Hauptthemen laut MEDLINE: Printing, Three-Dimensional. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Straumann Belgium, Labo Hoet Dental Lab, Intellident.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The aim of this study was to evaluate the accuracy of 3‐dimensional (3D)‐printed surgical guides for fully guided immediate implants from different manufacturers.

Methods

Eighteen 3D printed fully guided surgical guides (split into 3 groups [ n = 6] according to their manufacturer: Company, Desktop, or Lab), were used to place 72 implants ( n = 24) in identical maxillary models. After placement, the mean global, angular, mesiodistal, buccopalatal, and vertical deviation at the platform and apex of the placed implants, relative to their preoperatively planned positions, was calculated.

Results

Significant differences in global apex deviation, angular deviation, mesiodistal apex deviation, and vertical platform and apex deviation were found between the Lab and Desktop groups ( p ≤ 0.007). Significant differences in mesiodistal platform and apex deviation and buccopalatal apex deviation were also found between the Company and Desktop groups ( p ≤ 0.005). Finally, significant differences in buccopalatal apex deviation, and vertical platform and apex deviation were found between the Company and Lab groups ( p ≤ 0.003). Mean differences between guide groups across all parameters never exceeded 0.5 mm or 1°.

Conclusions

The choice of 3D printer has a significant effect on the accuracy of fully guided immediate implants. However, the clinical relevance of these differences may be considered limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalHumansImmediate Dental Implant LoadingSurgery, Computer-AssistedIn Vitro TechniquesMaxillaDental ImplantsModels, Dental

Stichwörter der Autor:innen

3‐dimensional‐printed surgical guideaccuracydental implantimmediatesingle tooth

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Periodontology and Oral Implantology, Faculty of Medicine and Health Sciences, Oral Health Sciences, Ghent University, Ghent, Belgium.

ORCID-Profile: Jeremy Pitman, Jan Cosyn, Véronique Christiaens, Faris Younes, Thomas de Bruyckere, Stijn Vervaeke, Maarten Glibert

Förderung

  • Straumann Belgium
  • Labo Hoet Dental Lab
  • Intellident

Zitieren

APA

Pitman, J., Cosyn, J., Christiaens, V., Younes, F., de Bruyckere, T., Vervaeke, S., & Glibert, M. (2024). Accuracy of immediately placed implants using surgical guides from different 3‐dimensional printers: An in vitro study. Clinical Implant Dentistry and Related Research, 26(5), 922-929. https://doi.org/10.1111/cid.13354

Vancouver

Pitman J, Cosyn J, Christiaens V, Younes F, de Bruyckere T, Vervaeke S, et al. Accuracy of immediately placed implants using surgical guides from different 3‐dimensional printers: An in vitro study. Clinical Implant Dentistry and Related Research. 2024;26(5):922-929. doi:10.1111/cid.13354

BibTeX
@article{Pitman2024,
  author = {Pitman, Jeremy and Cosyn, Jan and Christiaens, Véronique and Younes, Faris and de Bruyckere, Thomas and Vervaeke, Stijn and Glibert, Maarten},
  title = {Accuracy of immediately placed implants using surgical guides from different 3‐dimensional printers: An in vitro study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2024},
  volume = {26},
  number = {5},
  pages = {922--929},
  doi = {10.1111/cid.13354}
}
Kostenlos starten →