Does intra‐oral scan improve the impression accuracy of full‐arch implant‐supported prostheses: A systematic review and meta‐analysis
Clinical Implant Dentistry and Related Research · 2024-10 · 26 (5) · 847-861
DOI: 10.1111/cid.13321 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 22.03.2024. Verfasst von Zheng-Zhen Cai und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National…. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 69 Literaturangaben.
Abstract (Originalsprache)
Objectives
The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients. Materials and Methods Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3‐dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta‐analysis and a single‐armed meta‐analysis were conducted.
Results
A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of −99.29 μm (95% CI: [−141.38, −57.19], I 2 = 81%), while the result was opposite with the mean difference of 13.62 μm (95% CI: [10.97, 16.28], I 2 = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 μm (95% CI: [42.36, 109.86]) to 158.63 μm (95% CI: [−14.68, 331.93]).
Conclusions
Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory o…
- Department of Stomatology, Affiliated Hospital of Jiangnan University, Wuxi, China.
Zitieren
APA
Cai, Z. Z., Li, X., Wu, X. Y., Lai, H. C., & Shi, J. Y. (2024). Does intra‐oral scan improve the impression accuracy of full‐arch implant‐supported prostheses: A systematic review and meta‐analysis. Clinical Implant Dentistry and Related Research, 26(5), 847-861. https://doi.org/10.1111/cid.13321
Vancouver
Cai ZZ, Li X, Wu XY, Lai HC, Shi JY. Does intra‐oral scan improve the impression accuracy of full‐arch implant‐supported prostheses: A systematic review and meta‐analysis. Clinical Implant Dentistry and Related Research. 2024;26(5):847-861. doi:10.1111/cid.13321
BibTeX
@article{Cai2024,
author = {Cai, Zheng-Zhen and Li, Xin and Wu, Xin-Yu and Lai, Hong-Chang and Shi, Jun-Yu},
title = {Does intra‐oral scan improve the impression accuracy of full‐arch implant‐supported prostheses: A systematic review and meta‐analysis},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
volume = {26},
number = {5},
pages = {847--861},
doi = {10.1111/cid.13321}
}
EUVIMED