EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieOpen Access · CC BY 4.0

Marginal bone changes around platform‐switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial

Claudio Stacchi iD, Luca Lamazza iD, Antonio Rapani iD, Giuseppe Troiano iD, Marcello Messina, Alessandro Antonelli, Amerigo Giudice iD, Teresa Lombardi

Clinical Implant Dentistry and Related Research · 2023-04 · 25 (2) · 398-408

DOI: 10.1111/cid.13186 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Implant Dentistry and Related Research, 2023-02. Verfasst von Claudio Stacchi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy. Hauptthemen laut MEDLINE: Dental Implants, Alveolar Bone Loss, Mouth, Edentulous. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study analyzes early marginal bone modifications occurring around platform‐switched implants with conical connection placed 1 or 2 mm subcrestally.

Methods

This crossover randomized controlled trial enrolled partially edentulous patients needing two implants in either the posterior maxilla or mandible. Each patient received two platform‐switched implants with conical connection inserted 2 mm (Test) and 1 mm (Control) subcrestally. Definitive abutments were immediately connected and, after 4 months of unsubmerged healing, screwed metal‐ceramic crowns were delivered. Radiographs were taken at implant placement (T0), prosthesis delivery (T1), and after 1 year of prosthetic loading (T2).

Results

Fifty‐one patients (25 males and 26 females; mean age 61.2 ± 12.1 years) totaling 102 implants were included in the final analysis. Mean peri‐implant bone level (PBL) reduction from T0 to T2 was not significantly different around Test (0.49 ± 0.32 mm) and Control implants (0.46 ± 0.35 mm; p = 0.66). Multivariate linear regression models highlighted a significant positive correlation between history of periodontitis and PBL reduction. At T2, no Test group implant and 6 Control group implants exhibited PBL below the implant platform (11.8% of Control group implants).

Conclusion

No significant differences in peri‐implant marginal bone changes were demonstrated after 1 year of prosthetic loading between platform‐switched implants with conical connection inserted either 1 or 2 mm subcrestally. However, 2 mm subcrestal placement resulted in deeper implant positioning at T2, with no exposure of treated implant surface and potential preventive effect against subsequent peri‐implant pathology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsAlveolar Bone LossMouth, EdentulousMaleFemaleHumansMiddle AgedAgedDental Implantation, EndosseousProsthesis Implantation

Stichwörter der Autor:innen

conical connectionearly marginal bone lossperi-implantitissubcrestal implant placement

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
  • Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy.
  • Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
  • Private Practice, Trieste, Italy.
  • Department of Health Sciences, Magna Graecia University, Catanzaro, Italy.

ORCID-Profile: Claudio Stacchi, Luca Lamazza, Antonio Rapani, Giuseppe Troiano, Amerigo Giudice

Zitieren

APA

Stacchi, C., Lamazza, L., Rapani, A., Troiano, G., Messina, M., Antonelli, A., Giudice, A., & Lombardi, T. (2023). Marginal bone changes around platform‐switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial. Clinical Implant Dentistry and Related Research, 25(2), 398-408. https://doi.org/10.1111/cid.13186

Vancouver

Stacchi C, Lamazza L, Rapani A, Troiano G, Messina M, Antonelli A, et al. Marginal bone changes around platform‐switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial. Clinical Implant Dentistry and Related Research. 2023;25(2):398-408. doi:10.1111/cid.13186

BibTeX
@article{Stacchi2023,
  author = {Stacchi, Claudio and Lamazza, Luca and Rapani, Antonio and Troiano, Giuseppe and Messina, Marcello and Antonelli, Alessandro and Giudice, Amerigo and Lombardi, Teresa},
  title = {Marginal bone changes around platform‐switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2023},
  volume = {25},
  number = {2},
  pages = {398--408},
  doi = {10.1111/cid.13186}
}
Kostenlos starten →