Comparative Efficacy of Two Defocus Soft Contact Lenses on Axial Length and Choroid in High Myopic Adolescents
Clinical & Experimental Ophthalmology · 2026-07 · 54 (5) · 617-629
DOI: 10.1111/ceo.70120 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical & Experimental Ophthalmology, online erschienen am 24.04.2026. Verfasst von Jia Yu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Huade Ophthalmology Hospital Co., Ltd., Beijing, China. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Axial Length, Eye, Choroid, Myopia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
Background
To compare the 1‐year myopia control efficacy of two defocus soft contact lenses (SCLs) versus single‐vision spectacles in high myopic adolescents (spherical equivalent refraction [SER] of 6.00 diopters or more).
Methods
237 participants were randomised into three groups: peripheral gradual defocus SCLs (Group A), multipoint defocus SCLs (Group B) and single‐vision spectacles (Group C), with 12‐month follow‐up. Outcomes included axial length change (ΔAL), SER change (ΔSER), choroidal thickness (CT) and choroidal vascular density (VDCC).
Results
217 subjects completed follow‐up. From Month 3, Group B had the smallest ΔAL: 12‐month ΔAL was (0.12 ± 0.08) mm, significantly lower than Groups A (0.25 ± 0.10 mm) and C (0.48 ± 0.12 mm), all p < 0.001. Group B's ΔSER (−0.13 ± 0.09 D) was also smaller than Groups A (−0.24 ± 0.11 D) and C (−0.45 ± 0.13 D) (all p value less than 0.05). Group B showed increased VDCC/CT (notably 3‐mm foveal area), Group C decreased and Group A stabilised. Multiple regression indicated Group B intervention (β = −0.32, p = 0.002) and 3‐mm CT change (β = −0.28, p = 0.006) independently correlated with smaller ΔAL (model R 2 = 0.35, p value less than 0.001).
Conclusion
Multipoint defocus SCLs outperform other methods in controlling high myopia and improving choroidal parameters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Huade Ophthalmology Hospital Co., Ltd., Beijing, China.
- Ming Vision and Ophthalmology, Jianguomen Branch Clinic, Beijing, China.
- Ineye Hospital of Chengdu University of Traditional Medicine, Chengdu, China.
- Beijing Yushi Eye Clinic, Beijing, China.
ORCID-Profile: Jia Yu
Zitieren
APA
Yu, J., & Zhao, J. (2026). Comparative Efficacy of Two Defocus Soft Contact Lenses on Axial Length and Choroid in High Myopic Adolescents. Clinical & Experimental Ophthalmology, 54(5), 617-629. https://doi.org/10.1111/ceo.70120
Vancouver
Yu J, Zhao J. Comparative Efficacy of Two Defocus Soft Contact Lenses on Axial Length and Choroid in High Myopic Adolescents. Clinical & Experimental Ophthalmology. 2026;54(5):617-629. doi:10.1111/ceo.70120
BibTeX
@article{Yu2026,
author = {Yu, Jia and Zhao, Jie},
title = {Comparative Efficacy of Two Defocus Soft Contact Lenses on Axial Length and Choroid in High Myopic Adolescents},
journal = {Clinical & Experimental Ophthalmology},
year = {2026},
volume = {54},
number = {5},
pages = {617--629},
doi = {10.1111/ceo.70120}
}
EUVIMED