Investigating Microinvasive Intra‐Ocular Biopsy
Clinical & Experimental Ophthalmology · 2025-11 · 53 (8) · 996-1007
DOI: 10.1111/ceo.14591 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, online erschienen am 04.08.2025. Verfasst von Jared Ching und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Microtechnology, Yokohama City University Medical Centre, Yokohama, Japan. Hauptthemen laut MEDLINE: Biopsy, Needle, Uveal Melanoma, Retinoblastoma, Retinal Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Keeler Scholarship, T.F.C. Frost Charitable Trust.
Abstract (Originalsprache)
Background
Current minimally invasive methods of intraocular biopsy are confined to small gauge (G) needles and subretinal cannulae that can be prone to wound leakage at the biopsy site. We investigate the role of microneedles with internal diameters as small as 49G for intraocular biopsy in the posterior and anterior segments.
Methods
Human uveal melanoma (UM 92–1) and retinoblastoma (Y79) cancer cell lines were aspirated using microneedles of different sizes with a vitrectomy set up, and cell viability was analysed. Suspensions of cancer cells with fluorescent microbeads were injected into the subretinal space of fresh ex vivo porcine eyes before simulating biopsy with microneedle retinal puncture, followed by imaging with optical coherence tomography (OCT) and histology. Anterior chamber puncture was performed with microneedles and imaged with anterior segment OCT and examined for aqueous leakage.
Results
We find that microneedles can aspirate ocular cancer cells, both retinoblastoma and uveal melanoma, in vitro and retain a high level of cell viability, 72.83% (49G) compared to 97.00% (25G vitrector) in UM 92–1. Using an ex vivo porcine model, we find that a 49G microneedle creates a self‐sealing retinal wound that does not reflux microbeads of 200 nm in diameter. Further, we find that anterior chamber puncture with a microneedle via a corneal paracentesis results in no evidence of an aqueous leak (0%) compared to a leakage rate of 100% and 66% when using a 30G and 34G needle, respectively.
Conclusion
A microinvasive approach to biopsy intraocular specimens is feasible, warranting further in vivo studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology and Microtechnology, Yokohama City University Medical Centre, Yokohama, Japan.
- Department of Engineering Science, University of Oxford, Oxford, UK.
ORCID-Profile: Jared Ching
Förderung
- Keeler Scholarship
- T.F.C. Frost Charitable Trust
Zitieren
APA
Ching, J., Kitahata, S., Ichikawa, H., & Kadonosono, K. (2025). Investigating Microinvasive Intra‐Ocular Biopsy. Clinical & Experimental Ophthalmology, 53(8), 996-1007. https://doi.org/10.1111/ceo.14591
Vancouver
Ching J, Kitahata S, Ichikawa H, Kadonosono K. Investigating Microinvasive Intra‐Ocular Biopsy. Clinical & Experimental Ophthalmology. 2025;53(8):996-1007. doi:10.1111/ceo.14591
BibTeX
@article{Ching2025,
author = {Ching, Jared and Kitahata, Shohei and Ichikawa, Hinako and Kadonosono, Kazuaki},
title = {Investigating Microinvasive Intra‐Ocular Biopsy},
journal = {Clinical & Experimental Ophthalmology},
year = {2025},
volume = {53},
number = {8},
pages = {996--1007},
doi = {10.1111/ceo.14591}
}
EUVIMED