Intraocular lens power calculation accuracy in patients with keratoconus: Network meta‐analysis and systematic review
Clinical & Experimental Ophthalmology · 2025
DOI: 10.1111/ceo.14470 ↗Kurz gefasst
Netzwerk-Metaanalyse in der Zeitschrift Clinical & Experimental Ophthalmology, 2025. Verfasst von Olga Reitblat und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel. Hauptthemen laut MEDLINE: Biometry, Keratoconus, Lenses, Intraocular, Optics and Photonics. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Accurate intraocular lens (IOL) calculation in eyes with keratoconus (KCN) poses significant challenges. While various formulas, including KCN‐specific ones, have been investigated, the optimal calculation method remains inconclusive.
Methods
The study was pre‐registered in PROSPERO (CRD42023483119). PubMed, Embase and CENTRAL electronic databases were systematically searched for studies comparing IOL power calculation formulas in eyes with KCN. The percentage of eyes with a prediction error (PE) within ±0.50 D and ±1.00 D, the mean PE and the mean absolute error (MAE) were compared using a random effect model in Bayesian network meta‐analysis.
Results
Nine retrospective clinical studies were included, totalling 623 eyes and 25 calculation methods. The Barrett True‐K formula for KCN with measured posterior cornea (BTK MPC) achieved the highest ranking for the percentage of PE within ±0.50 D and ±1.00 D, mean PE, and MAE, with surface under the cumulative ranking (SUCRA) of 95%, 95%, 97% and 95%, respectively. Subgroup analysis showed that for the predictability rates within ±0.50 D and ±1.00 D, the best ranking formulas were: Emmetropia Verifying Optical (EVO) (85%) and BTK MPC (78%), respectively, in mild KCN; BTK with predicted posterior cornea (PPC) (85%) and MPC (88%), respectively, in moderate KCN; and Kane KCN for both metrics in severe KCN (84% and 95%, respectively).
Conclusion
The BTK MPC formula ranked highest across various metrics, suggesting its superior accuracy for IOL calculations in KCN. The optimal formulas may differ based on KCN severity, with current evidence suggesting potential advantage of Kane KCN for severe cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel.
- Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA.
ORCID-Profile: Olga Reitblat
Zitieren
APA
Reitblat, O., Sella, R., Zlatkin, R., Bahar, I., & Lerman, T. T. (2025). Intraocular lens power calculation accuracy in patients with keratoconus: Network meta‐analysis and systematic review. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.14470
Vancouver
Reitblat O, Sella R, Zlatkin R, Bahar I, Lerman TT. Intraocular lens power calculation accuracy in patients with keratoconus: Network meta‐analysis and systematic review. Clinical & Experimental Ophthalmology. 2025. doi:10.1111/ceo.14470
BibTeX
@article{Reitblat2025,
author = {Reitblat, Olga and Sella, Ruti and Zlatkin, Rita and Bahar, Irit and Lerman, Tsahi T},
title = {Intraocular lens power calculation accuracy in patients with keratoconus: Network meta‐analysis and systematic review},
journal = {Clinical & Experimental Ophthalmology},
year = {2025},
doi = {10.1111/ceo.14470}
}
EUVIMED