Prediction of refraction error after toric lens implantation with biometric input data uncertainties and power labelling tolerances
Clinical & Experimental Ophthalmology · 2025
DOI: 10.1111/ceo.14449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, 2025. Verfasst von Achim Langenbucher und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Ophthalmology, Saarland University, Saarbrücken, Germany. Hauptthemen laut MEDLINE: Biometry, Refraction, Ocular, Lenses, Intraocular, Lens Implantation, Intraocular. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The purpose of this study was to simulate the impact of biometric measure uncertainties, lens equivalent and toric power labelling tolerances and axis alignment errors on the refractive outcome after cataract surgery with toric lens implantation.
Methods
In this retrospective non‐randomised cross sectional Monte‐Carlo simulation study we evaluated a dataset containing 7458 LenStar 900 preoperative biometric measurements. The biometric uncertainties from literature, lens power labelling according to ISO 11979, and axis alignment tolerances of a modern toric lens (Hoya Vivinex) were taken to be normally distributed and used in a Monte‐Carlo simulation with 100 000 samples per eye. The target variable was the defocus equivalent (DEQ) derived using the Castrop (DEQ C ) and the Haigis (DEQ H ) formulae.
Results
Mean/median / 90% quantile DEQ C was 0.22/0.21/0.36 D and DEQ H was 0.20/0.19/0.32 D. Ignoring the variation in lens power labelling and toric axis alignment the respective DEQ C was 0.20/0.19/0.32 D and DEQ H was 0.18/0.17/0.29 D. DEQ C and DEQ H increased with shorter eyes, steeper corneas, equivalent lens power and highly with toric lens power.
Conclusions
According to our simulation results, uncertainties in biometric measures, lens power labelling tolerances, and axis alignment errors are responsible for a significant part of the refraction prediction error after cataract surgery with toric lens implantation. Additional labelling of the exact equivalent and toric power on the lens package could be a step to improve postoperative results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Experimental Ophthalmology, Saarland University, Saarbrücken, Germany.
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Saarbrücken, Germany.
- Department of Ophthalmology, Semmelweis-University, Budapest, Hungary.
- School of Physical Sciences, The Open University, Milton Keynes, UK.
- Great Lakes Eye Care, Saint Joseph, Michigan, USA.
- Department of Neurology and Ophthalmology, College of Osteopathic Medicine, Michigan State University, East Lansing, Michigan, USA.
ORCID-Profile: Achim Langenbucher, Jascha Wendelstein
Zitieren
APA
Langenbucher, A., Szentmáry, N., Cayless, A., Cooke, D., Hoffmann, P., & Wendelstein, J. (2025). Prediction of refraction error after toric lens implantation with biometric input data uncertainties and power labelling tolerances. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.14449
Vancouver
Langenbucher A, Szentmáry N, Cayless A, Cooke D, Hoffmann P, Wendelstein J. Prediction of refraction error after toric lens implantation with biometric input data uncertainties and power labelling tolerances. Clinical & Experimental Ophthalmology. 2025. doi:10.1111/ceo.14449
BibTeX
@article{Langenbucher2025,
author = {Langenbucher, Achim and Szentmáry, Nóra and Cayless, Alan and Cooke, David and Hoffmann, Peter and Wendelstein, Jascha},
title = {Prediction of refraction error after toric lens implantation with biometric input data uncertainties and power labelling tolerances},
journal = {Clinical & Experimental Ophthalmology},
year = {2025},
doi = {10.1111/ceo.14449}
}
EUVIMED