Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi‐modal ophthalmic parameters of anterior and posterior chamber
Clinical & Experimental Ophthalmology · 2024
DOI: 10.1111/ceo.14433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, 2024. Verfasst von Yijia Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Phakic Intraocular Lenses, Microscopy, Acoustic, Tomography, Optical Coherence, Lens Implantation, Intraocular. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Healthy Young Talents Project of Shanghai Municipal Health Commission, Shanghai Rising-Star Program, Project of Shanghai Science and Technology.
Abstract (Originalsprache)
Background
To establish a novel vault prediction formula after implantable collamer lens (ICL) implantation that considers both anterior and posterior chamber characteristics with multi‐modal parameters.
Methods
A total of 103 and 65 eyes were included in the development and validation groups, respectively. Exploratory factor analysis was performed using data from optical coherence tomography and ultrasound biomicroscopy in the development group to synthesise summative factors with different clinical significance. Dominant original metrics with heavy loadings on significant factors (absolute value of the loading coefficient >0.5) were screened for multivariate linear regression models using a stepwise method. The newly derived formula was evaluated and compared to the NK and KS formulas in the validation group.
Results
Six factors (anterior chamber angle, horizontal width, lens, iris, iridociliary complex and ciliary body) were generated after dimension reduction via factor analysis. Factors 2 (horizontal width), 3 (lens), and 5 (iridociliary complex) had a significant influence on the vault. When dominant metrics on these factors were screened for further model building, ICL size, anterior chamber width, crystalline lens rise, iris curvature, and iris‐ciliary process distance were retained in the final formula, with an adjusted R 2 of 0.698, a median absolute error of 81.97 mm, and a root‐mean‐square error of 103.35 mm.
Conclusions
Multiple intraocular components, including the lens, iris, and ciliary body, play important roles in vault determination. The new formula exhibits good accuracy for vault predictions and ICL size recommendations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China.
ORCID-Profile: Zhe Zhang, Xingtao Zhou, Jing Zhao
Förderung
- Healthy Young Talents Project of Shanghai Municipal Health Commission
- Shanghai Rising-Star Program
- Project of Shanghai Science and Technology
- National Natural Science Foundation of China
- Project of Shanghai Xuhui District Science and Technology
Zitieren
APA
Xu, Y., Liu, F., Ye, Y., Zhang, Z., Niu, L., Yao, P., Wang, X., Zhou, X., & Zhao, J. (2024). Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi‐modal ophthalmic parameters of anterior and posterior chamber. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.14433
Vancouver
Xu Y, Liu F, Ye Y, Zhang Z, Niu L, Yao P, et al. Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi‐modal ophthalmic parameters of anterior and posterior chamber. Clinical & Experimental Ophthalmology. 2024. doi:10.1111/ceo.14433
BibTeX
@article{Xu2024,
author = {Xu, Yijia and Liu, Fang and Ye, Yuhao and Zhang, Zhe and Niu, Lingling and Yao, Peijun and Wang, Xiaoying and Zhou, Xingtao and Zhao, Jing},
title = {Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi‐modal ophthalmic parameters of anterior and posterior chamber},
journal = {Clinical & Experimental Ophthalmology},
year = {2024},
doi = {10.1111/ceo.14433}
}
EUVIMED