Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic
Clinical Endocrinology · 2025
DOI: 10.1111/cen.15241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Endocrinology, 2025. Verfasst von Jeanne-Marie Nollen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Leiden University Medical Centre, Leiden, the Netherlands. Hauptthemen laut MEDLINE: Arginine Vasopressin. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: This study was funded by Academic Nursing Grant, Leiden University Medical Center (nr 2021-2001)., Leids Universitair Medisch Centrum.
Abstract (Originalsprache)
Objective
Detecting hypotonic urine (specific gravity < 1005 g/L) is crucial for the early identification of arginine vasopressin deficiency (AVP‐deficiency), a common complication after pituitary surgery. This study aimed to evaluate the agreement between urine specific gravity measurements taken by patients using urine test strips and those taken by nurses using a refractometer, to assess the reliability of patient‐conducted measurements for diagnosing this condition.
Design
A prospective cohort study was conducted in a neurosurgical ward. Patients The study included 110 participants who collectively provided 609 specific gravity measurements.
Measurements
Specific gravity measurements were taken using Combur‐10 urine test strips by patients and using an ATAGO MASTER‐SUR/Nα refractometer by nurses. Agreement was analysed using Weighted Kappa and intraclass correlation coefficient (ICC).
Results
Moderate agreement was found between patient‐conducted measurements and those from the refractometer (Kappa = 0.47, ICC = 0.69). Substantial to good agreement was observed between patient and nurse measurements using urine test strips (Kappa = 0.82, ICC = 0.89). A threshold of 1.015 g/L in test strip measurements ensured no cases of hypotonic urine were missed, reducing the need for nurse‐led testing by 50%. Patient satisfaction was high (mean 7.8), while nurse satisfaction was lower (mean 6.4).
Conclusions
Although patients are less accurate than nurses in measuring specific gravity, they can reliably screen for hypotonic urine in AVP‐deficiency diagnostics using urine test strips. A higher cut‐off point improves diagnostic accuracy, enhances patient participation and reduces the screening workload for nurses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurosurgery, Leiden University Medical Centre, Leiden, the Netherlands.
- Department of Quality and Patient Safety, Leiden University Medical Centre, Leiden, the Netherlands.
- Department of Endocrinology, Leiden University Medical Centre, Leiden, the Netherlands.
- Department of Biomedical Data Sciences, Leiden University Medical Centre, Leiden, the Netherlands.
Förderung
- This study was funded by Academic Nursing Grant, Leiden University Medical Center (nr 2021-2001).
- Leids Universitair Medisch Centrum
Zitieren
APA
Nollen, J. M., Brunsveld-Reinders, A. H., Biermasz, N. R., Verstegen, M. J. T., Leijtens, E., Peul, W. C., Steyerberg, E. W., & van Furth, W. R. (2025). Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic. Clinical Endocrinology. https://doi.org/10.1111/cen.15241
Vancouver
Nollen JM, Brunsveld-Reinders AH, Biermasz NR, Verstegen MJT, Leijtens E, Peul WC, et al. Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic. Clinical Endocrinology. 2025. doi:10.1111/cen.15241
BibTeX
@article{Nollen2025,
author = {Nollen, Jeanne-Marie and Brunsveld-Reinders, Anja H and Biermasz, Nienke R and Verstegen, Marco J T and Leijtens, Eline and Peul, Wilco C and Steyerberg, Ewout W and van Furth, Wouter R},
title = {Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic},
journal = {Clinical Endocrinology},
year = {2025},
doi = {10.1111/cen.15241}
}
EUVIMED