Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency
Clinical Endocrinology · 2024
DOI: 10.1111/cen.15074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Endocrinology, 2024. Verfasst von Katharine Lazarus und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, Imperial College Healthcare NHS Trust, London, UK. Hauptthemen laut MEDLINE: Adrenal Insufficiency, Hydrocortisone, Diagnostic Errors. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: George Alberti Research Training Fellow, the NIHR BRC, the NIHR, NIHR BRC.
Abstract (Originalsprache)
Background
Adrenal insufficiency (AI) is a life‐threatening condition which requires long term glucocorticoid replacement. The insulin tolerance test (ITT) is the current gold standard test for diagnosis of secondary AI, but the widely accepted cut‐off value of a peak cortisol of less than 500 nmol/L assumes that anyone who does not reach this value has AI and thus requires full replacement. The cut‐off used to diagnose AI is also founded on outdated assays. Use of this cut‐off in an era of more specific immunoassays therefore risks misdiagnosis, subsequent unnecessary glucocorticoid exposure and associated adverse effects with increased mortality risk. Design, Patients and Measurements This retrospective analysis assessed 300 ITT cortisol responses using the Abbott Architect and Alinity analyser platforms in patients with suspected AI over a period of 12 years (August 2010 to January 2022), at a tertiary centre.
Results
Patients were classified as having AI or not, based on a comprehensive clinical review of electronic patient records from the point of test to the present day by a panel of pituitary and adrenal specialists. Using the current institutional cut‐off value of 500 nmol/L, receiver operating characteristic analysis identified a 100.0% sensitivity and 43.6% specificity (area under the curve 0.979). Using a lower cortisol threshold value of 416 nmol/L on the Abbott analyser platform maintained a sensitivity of 100.0% and improved the specificity to 86.7%.
Conclusion
This data supports lowering the Abbott analyser ITT peak cortisol threshold to 416 nmol/L. Use of this improved cut‐off avoids unnecessary glucocorticoid replacement therapy in 104 (34.7%) of individuals in this study. All patients remained well with at least 1 year longitudinal follow up of glucocorticoid replacement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Endocrinology, Imperial College Healthcare NHS Trust, London, UK.
- Department of Metabolism, Digestion and Reproduction, Division of Diabetes, Endocrinology and Metabolism, Imperial College London, London, UK.
- Department of Clinical Biochemistry, North West London Pathology, London, UK.
Förderung
- George Alberti Research Training Fellow
- the NIHR BRC
- the NIHR, NIHR BRC
- the Moulton Charitable Research Foundation
Zitieren
APA
Lazarus, K., Hayes, A., Narula, K., Papadopolou, D., Tan, T. M., Meeran, K., & Choudhury, S. (2024). Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency. Clinical Endocrinology. https://doi.org/10.1111/cen.15074
Vancouver
Lazarus K, Hayes A, Narula K, Papadopolou D, Tan TM, Meeran K, et al. Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency. Clinical Endocrinology. 2024. doi:10.1111/cen.15074
BibTeX
@article{Lazarus2024,
author = {Lazarus, Katharine and Hayes, Annabel and Narula, Kavita and Papadopolou, Debbie and Tan, Tricia M-M and Meeran, Karim and Choudhury, Sirazum},
title = {Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency},
journal = {Clinical Endocrinology},
year = {2024},
doi = {10.1111/cen.15074}
}
EUVIMED