Comparison of 4D computed tomography and F‐18 fluorocholine PET for localisation of parathyroid lesions in primary hyperparathyroidism: A systematic review and meta‐analysis
Clinical Endocrinology · 2023-09 · 99 (3) · 262-271
DOI: 10.1111/cen.14875 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Clinical Endocrinology, online erschienen am 08.01.2023. Verfasst von Dhrumil Deveshkumar Patel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seth G.S. Medical college & King Edward Memorial hospital, Mumbai, India. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Hyperparathyroidism, Primary. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Minimally invasive parathyroidectomy (MIP) is the standard of care for primary hyperparathyroidism (PHPT). Four dimensional computed tomography(4DCT) and F‐18 Fluorocholine positron emission tomography/computed tomography (FCH PET/CT) localize adenomas accurately to perform MIP. We aimed to conduct a systematic review and metanalysis to evaluate the diagnostic performance of 4DCT and FCH PET/CT scan for quadrant wise localisation in PHPT patients and to do head‐to‐head comparison between these two modalities. Design, Patients and Measurement After searching through PubMed and EMBASE databases, 46 studies (using histology as a gold standard) of 4DCT and FCH PET/CT were included.
Results
Total number of patients included were 1651 and 952 for 4DCT scan (studies n = 26) and FCH PET/CT scan (studies n = 24) respectively. In per patient analysis, FCH PET/CT and 4DCT had pooled sensitivities of 92% (88−94) and 85% (73−92) respectively and in per lesion analysis, 90% (86−93) and 79% (71−84), respectively. In the subgroup with negative conventional imaging/persistent PHPT, FCH PET/CT had comparable sensitivity to 4DCT (84% [74−90] vs. 72% [46−88]). As per patient wise analysis, FCH PET/CT had better detection rates than 4DCT ([92.4 vs. 76.85], odds ratio −3.89 [1.6−9.36] p = .0024) in the subpopulation where both FCH PET/CT and 4DCT were reported.
Conclusion
Both 4DCT and FCH PET/CT scan performed well in newly diagnosed patients, patients with persistent disease and in those with inconclusive conventional imaging results. FCH PET/CT scan had a higher pooled sensitivity than 4DCT in detecting patients with PHPT in head to head comparison.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Seth G.S. Medical college & King Edward Memorial hospital, Mumbai, India.
- Department of Pharmacology, Post-graduate Institute of Medical Education and Research, Chandigarh, India.
- Department of Rheumatology, Post-graduate Institute of Medical Education and Research, Chandigarh, India.
- Consultant and head of department of nuclear medicine and PET/CT, Sanjeevani CBCC USA Cancer hospital, Raipur, India.
- Department of Radiology, G.M.E.R.S. Medical college and hospital, Junagadh, India.
- Department of Endocrinology and metabolism, Seth G.S. Medical College & King Edward Memorial hospital, Mumbai, India.
ORCID-Profile: Dhrumil Deveshkumar Patel, Samiksha Bhattacharjee, Chirag Rajkumar Kopp, Abhiram G Ashwathanarayana, Rohit Barnabas, Sanjay Kumar Bhadada, Manjunath Havalappa Dodamani
Zitieren
APA
Patel, D. D., Bhattacharjee, S., Pandey, A. K., Kopp, C. R., Ashwathanarayana, A. G., Patel, H. V., Barnabas, R., Bhadada, S. K., & Dodamani, M. H. (2023). Comparison of 4D computed tomography and F‐18 fluorocholine PET for localisation of parathyroid lesions in primary hyperparathyroidism: A systematic review and meta‐analysis. Clinical Endocrinology, 99(3), 262-271. https://doi.org/10.1111/cen.14875
Vancouver
Patel DD, Bhattacharjee S, Pandey AK, Kopp CR, Ashwathanarayana AG, Patel HV, et al. Comparison of 4D computed tomography and F‐18 fluorocholine PET for localisation of parathyroid lesions in primary hyperparathyroidism: A systematic review and meta‐analysis. Clinical Endocrinology. 2023;99(3):262-271. doi:10.1111/cen.14875
BibTeX
@article{Patel2023,
author = {Patel, Dhrumil Deveshkumar and Bhattacharjee, Samiksha and Pandey, Avaneesh Kumar and Kopp, Chirag Rajkumar and Ashwathanarayana, Abhiram G and Patel, Himani Vinayak and Barnabas, Rohit and Bhadada, Sanjay Kumar and Dodamani, Manjunath Havalappa},
title = {Comparison of 4D computed tomography and F‐18 fluorocholine PET for localisation of parathyroid lesions in primary hyperparathyroidism: A systematic review and meta‐analysis},
journal = {Clinical Endocrinology},
year = {2023},
volume = {99},
number = {3},
pages = {262--271},
doi = {10.1111/cen.14875}
}
EUVIMED