Comparing Hip, Wrist and Ankle‐Worn ActiGraph Accelerometers for Measuring Physical Activity in Toddlers
Child: Care, Health and Development · 2025
DOI: 10.1111/cch.70074 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Child: Care, Health and Development, 2025. Verfasst von Tze-Hsuan Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Health, Oregon State University, Corvallis, Oregon, USA. Hauptthemen laut MEDLINE: Exercise, Accelerometry, Actigraphy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Caplan Foundation for Early Childhood, Ministry of Education of Taiwan.
Abstract (Originalsprache)
Background
Understanding the relationships among accelerometer placements and the agreements between cut points is essential to enhancing the accuracy of physical activity measurement for toddlers. This study aimed to compare the magnitudes and relationships of activity counts from hip, wrist and ankle ActiGraph GT9X accelerometers in toddlers and to assess the agreement between age‐specific cut points at group and individual levels.
Methods
Accelerometer data were collected from nine toddlers (three girls, 22.2 ± 6.1 months) during 12 weekly 20‐min free‐play sessions. Activity counts were downloaded using specific epoch lengths and filters according to the studies validating the cut points. One‐way repeated ANOVAs were used to compare the activity counts per 15 s across placements. Interplacement relationships were examined using Spearman's rank correlation coefficients. Agreements were assessed with Bland–Altman plots between three sets of hip cut points and one wrist cut point. Ankle data were not analysed because of a lack of validated cut points.
Results
The wrist placement yielded the highest counts, followed by ankle and hip. The correlation coefficient was strongest between hip and ankle vector magnitude counts ( rs = 0.88), whereas relatively weaker between wrist and hip ( rs = 0.65) and wrist and ankle ( rs = 0.60). The Bland–Altman plots indicated that time estimates for sedentary, light and moderate‐to‐vigorous physical activity were significantly different between most cut points. At the individual level, considerable variations in interplacement correlations and physical activity time estimates were observed.
Conclusion
The strong correlation between hip and ankle activity counts suggests that the ankle could be a feasible sensor‐wearing location. The moderate correlation between wrist and hip suggests that multiple accelerometers may be needed to enhance accuracy. Discrepancies across cut points indicate that more research is needed to validate cut points for accurately measuring physical activity in toddlers, especially considering individual differences in movement behaviours.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Health, Oregon State University, Corvallis, Oregon, USA.
- Collaborative Robotics and Intelligent Systems (CoRIS) Institute, Oregon State University, Corvallis, Oregon, USA.
- College of Science, Oregon State University, Corvallis, Oregon, USA.
ORCID-Profile: Tze-Hsuan Wang, Ameer Helmi, Rafael Morales Mayoral, Lucas Yao, April Murray, Naomi T Fitter, Samuel W Logan
Förderung
- Caplan Foundation for Early Childhood
- Ministry of Education of Taiwan
Zitieren
APA
Wang, T. H., Helmi, A., Mayoral, R. M., Yao, L., Murray, A., Fitter, N. T., & Logan, S. W. (2025). Comparing Hip, Wrist and Ankle‐Worn ActiGraph Accelerometers for Measuring Physical Activity in Toddlers. Child: Care, Health and Development. https://doi.org/10.1111/cch.70074
Vancouver
Wang TH, Helmi A, Mayoral RM, Yao L, Murray A, Fitter NT, et al. Comparing Hip, Wrist and Ankle‐Worn ActiGraph Accelerometers for Measuring Physical Activity in Toddlers. Child: Care, Health and Development. 2025. doi:10.1111/cch.70074
BibTeX
@article{Wang2025,
author = {Wang, Tze-Hsuan and Helmi, Ameer and Mayoral, Rafael Morales and Yao, Lucas and Murray, April and Fitter, Naomi T and Logan, Samuel W},
title = {Comparing Hip, Wrist and Ankle‐Worn ActiGraph Accelerometers for Measuring Physical Activity in Toddlers},
journal = {Child: Care, Health and Development},
year = {2025},
doi = {10.1111/cch.70074}
}
EUVIMED