Intra/inter‐observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery
BJU International · 2024
DOI: 10.1111/bju.16353 ↗Kurz gefasst
Fachartikel in der Zeitschrift BJU International, 2024. Verfasst von Manuela Tutolo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, University Hospitals Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Observer Variation, Cystoscopy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
To assess the intra/inter‐observer reliability of cystoscopic sphincter evaluation (CSE) in men undergoing sling surgery for urinary incontinence and if possible to evaluate its correlation with the final clinical decision. Patients and methods Two expert urologists prospectively filmed and recorded, incontinent patient's cystoscopies according to a standard scenario. Anonymised recordings where randomly offered to the same observer twice. The observers (medical students, urology residents and full urologist with 0–5, 5–10, >10 years of practice, respectively) were asked to assess and score the recordings without knowing any of the patients’ characteristics.
Results
In total, 37 recordings were scored twice by the 26 observers. The intraclass correlation coefficient (ICC) for intra‐observer reliability of the CSE was 0.54 (moderate), 0.58 (moderate) and 0.60 (substantial) for medical students, residents, and urologists, respectively. However, when stratifying observers according to their experience, the lowest agreement values were found between experts with >10 years of experience. The inter‐observer reliability for the CSE ICCs ranged between 0.31and 0.53, with the lowest ICC value observed between urologists (0.31).
Conclusions
The study demonstrates poor intra‐ and inter‐observer reliability of the CSE. According to these results, a CSE does not add valuable information to the clinical evaluation. In this scenario, it should not be considered in isolation from the patient's characteristics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, University Hospitals Leuven, Leuven, Belgium.
- Division of Oncology, Unit of Urology, Urological Research Institute, IRCCS Ospedale San Raffaele, Milan, Italy.
- Interuniversity Centre for Biostatistics and Statistical Bioinformatics, Leuven, Belgium.
- Leuven Institute for Healthcare Policy, Leuven, Belgium.
ORCID-Profile: Manuela Tutolo
Zitieren
APA
Tutolo, M., Laenen, A., Rosiello, G., De Ridder, D., Bruyneel, L., Cornelissen, J., & Van der Aa, F. (2024). Intra/inter‐observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery. BJU International. https://doi.org/10.1111/bju.16353
Vancouver
Tutolo M, Laenen A, Rosiello G, De Ridder D, Bruyneel L, Cornelissen J, et al. Intra/inter‐observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery. BJU International. 2024. doi:10.1111/bju.16353
BibTeX
@article{Tutolo2024,
author = {Tutolo, Manuela and Laenen, Annouschka and Rosiello, Giuseppe and De Ridder, Dirk and Bruyneel, Luk and Cornelissen, Jan and Van der Aa, Frank},
title = {Intra/inter‐observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery},
journal = {BJU International},
year = {2024},
doi = {10.1111/bju.16353}
}
EUVIMED