EUVIMEDEUVIMED entdecken
Crossref

Objective measurement of respiratory loudness in dogs with brachycephalic obstructive airway syndrome before and after corrective surgery

A A Turner iD, M R Joffe iD, G S Meyerowitz-Katz, A S Levien

Australian Veterinary Journal · 2025

DOI: 10.1111/avj.13456 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Australian Veterinary Journal, 2025. Verfasst von A A Turner und 3 weiteren Autor:innen. Beteiligte Einrichtung: Veterinary Specialists of Sydney, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Airway Obstruction, Craniosynostoses, Dog Diseases. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To quantify the intensity of sound associated with breathing in brachycephalic dogs and determine detectability on a mobile phone application (app). In addition, analyse differences in sound volume before and after sedation, and 2 weeks post‐surgical treatment of brachycephalic obstructive airway syndrome (BOAS). Study Design Clinical prospective pilot study. Animals 28 brachycephalic dogs.

Methods

A mobile phone app was used to measure and record the sound of breathing in decibels (dB) in a quiet room before and after sedation, as well as 10–14 days following corrective surgery. Statistical analysis was performed to determine if there was an improvement in breathing volume between each time point.

Results

Prior to sedation, the mean sound intensity was 30.8 dB. After sedation of 5 minutes, it decreased significantly to 25.8 dB (p = 0.0013). At the post‐operative consultation (10–14 days later), the mean intensity had further declined to 22.9 dB, significantly lower than both pre‐sedation and post‐sedation values ( P < 0.001).

Conclusion

The intensity of a brachycephalic patient's breathing is detectable by a mobile phone app and significantly reduces following surgical treatment involving palatoplasty, sacculectomy and alarplasty. Clinical Significance With further research, the loudness of breathing may prove to be a useful, readily available, objective measurement tool to add to the current BOAS grading systems, allowing communication between veterinarians regarding the severity of BOAS. Future prospective studies may also involve the correlation of measurements with the risk of complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Airway ObstructionCraniosynostosesDog DiseasesAnimalsDogsPilot ProjectsProspective StudiesMaleFemale

Autor:innen und Institutionen

  • Veterinary Specialists of Sydney, Sydney, New South Wales, Australia.
  • University of Wollongong, Wollongong, New South Wales, Australia.

ORCID-Profile: A A Turner, M R Joffe

Zitieren

APA

Turner, A. A., Joffe, M. R., Meyerowitz-Katz, G. S., & Levien, A. S. (2025). Objective measurement of respiratory loudness in dogs with brachycephalic obstructive airway syndrome before and after corrective surgery. Australian Veterinary Journal. https://doi.org/10.1111/avj.13456

Vancouver

Turner AA, Joffe MR, Meyerowitz-Katz GS, Levien AS. Objective measurement of respiratory loudness in dogs with brachycephalic obstructive airway syndrome before and after corrective surgery. Australian Veterinary Journal. 2025. doi:10.1111/avj.13456

BibTeX
@article{Turner2025,
  author = {Turner, A A and Joffe, M R and Meyerowitz-Katz, G S and Levien, A S},
  title = {Objective measurement of respiratory loudness in dogs with brachycephalic obstructive airway syndrome before and after corrective surgery},
  journal = {Australian Veterinary Journal},
  year = {2025},
  doi = {10.1111/avj.13456}
}
Kostenlos starten →