EUVIMEDEUVIMED entdecken
Open Access

Exploratory Analysis of Intraoperative Time Structure During the Initial Clinical Experience With Minimally Invasive Laparoscopic and Robotic Surgery ( MILAR ) Using the da Vinci SP System

Yuki Takenaka iD, Tsutomu Hayashi iD, Maho Takuwa iD, Yurina Fujisaki iD, Rei Ogawa iD, Ayako Kamiya iD, Takeyuki Wada iD, Yukinori Yamagata iD, Yusuke Kinugasa iD, Masanori Tokunaga iD, Takaki Yoshikawa iD, Yasuyuki Seto

Asian Journal of Endoscopic Surgery · 2026-01 · 19 (1)

DOI: 10.1111/ases.70356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Journal of Endoscopic Surgery, online erschienen am 28.07.2026. Verfasst von Yuki Takenaka und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastric Surgery, National Cancer Center Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Operative Time, Laparoscopy, Gastrectomy. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Robotic gastrectomy has been adopted for gastric cancer. However, operative time remains longer than that of laparoscopic surgery. Junk time has been proposed as a major contributor to prolonged operative duration. This study evaluated intraoperative time structure during the initial clinical experience with the minimally invasive laparoscopic and robotic (MILAR) approach using the da Vinci SP system.

Methods

This retrospective exploratory workflow analysis included consecutive patients who underwent robot‐assisted distal gastrectomy with D1+/D2 lymphadenectomy between May 2024 and June 2025. Patients were divided into the SP (MILAR) group and the conventional multi‐port robotic (Xi) group. Operative videos from skin incision to gastric transection were reviewed to quantify effective time and junk time.

Results

A total of 40 patients were analyzed (SP, n = 11; Xi, n = 29). Total operative time was significantly shorter in the SP group than in the Xi group (148.0 vs. 204.0 min, p = 0.001). Junk time was significantly reduced (30.4 vs. 36.6 min, p = 0.034), accompanied by fewer robotic instrument exchanges (4 vs. 46, p < 0.001). Effective time was shorter in the SP group; although this finding may have been influenced by surgeon expertise and case complexity. No increase in procedure‐related complications was observed in the SP group.

Conclusions

The present exploratory study describes differences in intraoperative time structure observed during the initial clinical experience with the MILAR approach using SP system. These findings provide insight into workflow characteristics of a hybrid team‐based approach and warrant further evaluation in prospective studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresOperative TimeLaparoscopyGastrectomyStomach NeoplasmsHumansRetrospective StudiesFemaleMaleMiddle AgedAgedLymph Node ExcisionWorkflow

Stichwörter der Autor:innen

MILARda Vinci SPintraoperative time structurejunk timerobotic gastrectomysingle‐port surgery

Autor:innen und Institutionen

  • Department of Gastric Surgery, National Cancer Center Hospital, Tokyo, Japan.
  • Department of Gastrointestinal Surgery, Institute of Science Tokyo, Tokyo, Japan.
  • Department of Gastrointestinal Surgery, Yokohama City University, Yokohama, Japan.

ORCID-Profile: Yuki Takenaka, Tsutomu Hayashi, Maho Takuwa, Yurina Fujisaki, Rei Ogawa, Ayako Kamiya, Takeyuki Wada, Yukinori Yamagata, Yusuke Kinugasa, Masanori Tokunaga, Takaki Yoshikawa

Zitieren

APA

Takenaka, Y., Hayashi, T., Takuwa, M., Fujisaki, Y., Ogawa, R., Kamiya, A., Wada, T., Yamagata, Y., Kinugasa, Y., Tokunaga, M., Yoshikawa, T., & Seto, Y. (2026). Exploratory Analysis of Intraoperative Time Structure During the Initial Clinical Experience With Minimally Invasive Laparoscopic and Robotic Surgery ( MILAR ) Using the da Vinci SP System. Asian Journal of Endoscopic Surgery, 19(1). https://doi.org/10.1111/ases.70356

Vancouver

Takenaka Y, Hayashi T, Takuwa M, Fujisaki Y, Ogawa R, Kamiya A, et al. Exploratory Analysis of Intraoperative Time Structure During the Initial Clinical Experience With Minimally Invasive Laparoscopic and Robotic Surgery ( MILAR ) Using the da Vinci SP System. Asian Journal of Endoscopic Surgery. 2026;19(1). doi:10.1111/ases.70356

BibTeX
@article{Takenaka2026,
  author = {Takenaka, Yuki and Hayashi, Tsutomu and Takuwa, Maho and Fujisaki, Yurina and Ogawa, Rei and Kamiya, Ayako and Wada, Takeyuki and Yamagata, Yukinori and Kinugasa, Yusuke and Tokunaga, Masanori and Yoshikawa, Takaki and Seto, Yasuyuki},
  title = {Exploratory Analysis of Intraoperative Time Structure During the Initial Clinical Experience With Minimally Invasive Laparoscopic and Robotic Surgery ( MILAR ) Using the da Vinci SP System},
  journal = {Asian Journal of Endoscopic Surgery},
  year = {2026},
  volume = {19},
  number = {1},
  doi = {10.1111/ases.70356}
}
Kostenlos starten →