EUVIMEDEUVIMED entdecken
Open Access

Development and Dry‐Lab Evaluation of a Novel Clothoid Curve Needle for Laparoscopic Suturing

Takeru Matsuda, Munenori Uemua iD, Kazunobu Hashikawa, Takashi Kato, Shingo Kanaji, Yoshihiro Kakeji

Asian Journal of Endoscopic Surgery · 2026-01 · 19 (1)

DOI: 10.1111/ases.70318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Journal of Endoscopic Surgery, online erschienen am 25.05.2026. Verfasst von Takeru Matsuda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastrointestinal Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan. Hauptthemen laut MEDLINE: Laparoscopy, Suture Techniques, Needles. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intracorporeal suturing in minimally invasive surgery remains technically demanding due to limited maneuverability and confined working space. Conventional suturing needles with fixed curvature can cause excessive tissue stress and irregular suture lines. We developed a novel surgical needle incorporating a clothoid (Euler spiral) curve, designed to provide smoother penetration and improved tip control.

Methods

A prospective, single‐center, crossover study was conducted using a laparoscopic dry‐lab simulator to compare a clothoid curve needle with a conventional curved needle. Sixteen surgeons (6 experts, 10 nonexperts) performed standardized laparoscopic suturing tasks with both needles. Objective evaluation of tissue displacement was recorded by internal sensors, capturing maximum deviation in three axes: X (left–right), Y (anterior–posterior), and Z (vertical). Subjective usability was assessed using an 8‐item Likert scale.

Results

Objective analysis revealed that experts showed reduced displacement with the clothoid needle in the Z direction ( p = 0.031), while nonexperts showed less deviation in the Y direction ( p = 0.019). In the overall cohort, Y ‐axis deviation was also significantly lower with the clothoid needle ( p = 0.038). The clothoid needle showed significantly higher Likert scores in thread pulling ( p < 0.001), smoothness of needle driving ( p = 0.031), tip control ( p = 0.008), tissue penetration resistance ( p = 0.045), and overall satisfaction ( p < 0.001).

Conclusion

The clothoid needle may offer potential advantages in selected aspects of laparoscopic suturing performance, although the effects differed according to operator experience and displacement axis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopySuture TechniquesNeedlesHumansProspective StudiesEquipment DesignCross-Over StudiesClinical Competence

Stichwörter der Autor:innen

clothoid curveclothoid needlelaparoscopic suturing

Autor:innen und Institutionen

  • Division of Gastrointestinal Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Division of Minimally Invasive Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Division of Biomedical Engineering, Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto, Japan.
  • Department of Plastic and Reconstructive Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Esophageal Surgery, Gastroenterological Center, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.

ORCID-Profile: Munenori Uemua

Zitieren

APA

Matsuda, T., Uemua, M., Hashikawa, K., Kato, T., Kanaji, S., & Kakeji, Y. (2026). Development and Dry‐Lab Evaluation of a Novel Clothoid Curve Needle for Laparoscopic Suturing. Asian Journal of Endoscopic Surgery, 19(1). https://doi.org/10.1111/ases.70318

Vancouver

Matsuda T, Uemua M, Hashikawa K, Kato T, Kanaji S, Kakeji Y. Development and Dry‐Lab Evaluation of a Novel Clothoid Curve Needle for Laparoscopic Suturing. Asian Journal of Endoscopic Surgery. 2026;19(1). doi:10.1111/ases.70318

BibTeX
@article{Matsuda2026,
  author = {Matsuda, Takeru and Uemua, Munenori and Hashikawa, Kazunobu and Kato, Takashi and Kanaji, Shingo and Kakeji, Yoshihiro},
  title = {Development and Dry‐Lab Evaluation of a Novel Clothoid Curve Needle for Laparoscopic Suturing},
  journal = {Asian Journal of Endoscopic Surgery},
  year = {2026},
  volume = {19},
  number = {1},
  doi = {10.1111/ases.70318}
}
Kostenlos starten →