Safety and Feasibility of Robotic Liver Parenchymal Transection Using the Saline‐Linked Cautery Method: A Propensity Score‐Matched Analysis With Laparoscopic Liver Resection
Asian Journal of Endoscopic Surgery · 2026-01 · 19 (1)
DOI: 10.1111/ases.70280 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Journal of Endoscopic Surgery, online erschienen am 24.03.2026. Verfasst von Yusuke Uemoto und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Kokura Memorial Hospital, Kitakyushu, Japan. Hauptthemen laut MEDLINE: Hepatectomy, Laparoscopy, Robotic Surgical Procedures, Liver Neoplasms. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Despite its advantages over open and laparoscopic approaches, robotic liver parenchymal transection is difficult because of the lack of a standardized method. Saline‐linked cautery (SLiC) method during robotic liver parenchymal transection was previously reported. To verify the safety and practicality of the SLiC method, the perioperative outcomes of laparoscopic liver resection (LLR) and robotic liver resection (RLR) were compared using propensity score matching (PSM).
Methods
LLRs and RLRs at our institution were analyzed from 2017 to 2024. Liver parenchymal transection of LLRs was performed using laparoscopic coagulating shears or cavitron ultrasonic surgical aspirator, and that of RLRs was performed using the SLiC method. Patient characteristics, surgical factors, and tumor factors were adjusted using PSM. Perioperative outcomes were compared between the LLR and RLR groups.
Results
LLR was performed in 145 patients and RLR in 129. Before PSM, tumor size was significantly larger in LLRs than in RLRs, whereas the rate of repeat hepatectomy was significantly higher. Blood loss was significantly lower in RLRs. After PSM, 94 cases were matched and analyzed. RLR substantially reduced intraoperative blood loss (63 mL in LLR vs. 15 mL in RLR, p < 0.01). Multivariate analysis for a higher amount of blood loss showed that the RLR was an independent risk‐reducing factor.
Conclusion
Comparable perioperative outcomes were observed between RLRs and LLRs, indicating that RLR can be performed safely and practically. The SLiC method is one of the preferred techniques for safer RLR with less blood loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Kokura Memorial Hospital, Kitakyushu, Japan.
ORCID-Profile: Yusuke Uemoto, Kei Harada
Zitieren
APA
Uemoto, Y., Harada, K., & Fujikawa, T. (2026). Safety and Feasibility of Robotic Liver Parenchymal Transection Using the Saline‐Linked Cautery Method: A Propensity Score‐Matched Analysis With Laparoscopic Liver Resection. Asian Journal of Endoscopic Surgery, 19(1). https://doi.org/10.1111/ases.70280
Vancouver
Uemoto Y, Harada K, Fujikawa T. Safety and Feasibility of Robotic Liver Parenchymal Transection Using the Saline‐Linked Cautery Method: A Propensity Score‐Matched Analysis With Laparoscopic Liver Resection. Asian Journal of Endoscopic Surgery. 2026;19(1). doi:10.1111/ases.70280
BibTeX
@article{Uemoto2026,
author = {Uemoto, Yusuke and Harada, Kei and Fujikawa, Takahisa},
title = {Safety and Feasibility of Robotic Liver Parenchymal Transection Using the Saline‐Linked Cautery Method: A Propensity Score‐Matched Analysis With Laparoscopic Liver Resection},
journal = {Asian Journal of Endoscopic Surgery},
year = {2026},
volume = {19},
number = {1},
doi = {10.1111/ases.70280}
}