Close Contact Transillumination Light Guides Surgeon to Vaginal Point Aa: Pharus Method for Robot‐Assisted Sacrocolpopexy
Asian Journal of Endoscopic Surgery · 2025
DOI: 10.1111/ases.13412 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Journal of Endoscopic Surgery, 2025. Verfasst von Akiko Yoshida Ueno und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Kochi Health Sciences Center, Kochi, Japan. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Transillumination. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
In robot‐assisted sacrocolpopexy (RSC) for patients with cystocele, accurate identification of the vaginal point Aa from the serosal side is crucial for surgical mesh placement in the appropriate position. We developed a novel Pharus method for exactly locating the point Aa for RSC.
Methods
In the Pharus method, the tip of a rigid endoscope was placed directly on the vaginal point Aa. In a preliminary experiment, we observed LED lights with different wavelengths of 450–870 nm using the Firefly imaging system to evaluate which wavelengths of light were captured by the Firefly mode. In a clinical study, the Pharus method was employed in four patients with Stage II or more advanced cystocele undergoing RSC. For comparison, a near‐infrared fluorescence method by indocyanine green (ICG) tattooing at the point Aa was also performed. The visibility of each method was evaluated under Firefly‐mode imaging.
Results
In the preliminary experiment, visible LED lights with wavelengths ≤ 720 nm, and near‐infrared LED lights with wavelengths ≥ 830 nm were detected by the Firefly mode. In RSC using the Pharus method, the point Aa of each patient was clearly highlighted as a green spot from the serosal side by the endoscopic white light penetrating the vaginal wall with a thickness of 3.3–4.6 mm. Compared with the ICG tattooing method, the Pharus method showed superior visibility in all patients.
Conclusion
The transillumination light effectively guided the surgeon to the vaginal point Aa, which can be likened to the Latin word “pharus,” meaning lighthouse.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Kochi Health Sciences Center, Kochi, Japan.
- Graduate School of Integrated Arts and Sciences, Medicine Program (Doctoral Course), Kochi Medical School, Nankoku, Japan.
- Department of Cardiovascular Control, Kochi Medical School, Nankoku, Japan.
- Department of Human Health and Medical Sciences, Hospital Administration Section, Kochi Medical School, Nankoku, Japan.
ORCID-Profile: Akiko Yoshida Ueno
Zitieren
APA
Yoshida Ueno, A., Sato, T., Kobayashi, M., Wakatsuki, S., Namba, T., & Hayashi, K. (2025). Close Contact Transillumination Light Guides Surgeon to Vaginal Point Aa: Pharus Method for Robot‐Assisted Sacrocolpopexy. Asian Journal of Endoscopic Surgery. https://doi.org/10.1111/ases.13412
Vancouver
Yoshida Ueno A, Sato T, Kobayashi M, Wakatsuki S, Namba T, Hayashi K. Close Contact Transillumination Light Guides Surgeon to Vaginal Point Aa: Pharus Method for Robot‐Assisted Sacrocolpopexy. Asian Journal of Endoscopic Surgery. 2025. doi:10.1111/ases.13412
BibTeX
@article{YoshidaUeno2025,
author = {Yoshida Ueno, Akiko and Sato, Takayuki and Kobayashi, Michiya and Wakatsuki, Shinya and Namba, Takaomi and Hayashi, Kazutoshi},
title = {Close Contact Transillumination Light Guides Surgeon to Vaginal Point Aa: Pharus Method for Robot‐Assisted Sacrocolpopexy},
journal = {Asian Journal of Endoscopic Surgery},
year = {2025},
doi = {10.1111/ases.13412}
}
EUVIMED