Factors affecting the use of a three‐dimensional model during robot‐assisted partial nephrectomy
Asian Journal of Endoscopic Surgery · 2024
DOI: 10.1111/ases.13301 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Journal of Endoscopic Surgery, 2024. Verfasst von Masahiro Yamazaki und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Sano Kosei General Hospital, Tochigi, Japan. Hauptthemen laut MEDLINE: Robotics, Robotic Surgical Procedures, Kidney Neoplasms. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Introduction
This study aimed to identify cases that require a three‐dimensional‐printed kidney model in robot‐assisted partial nephrectomy.
Methods
We enrolled 93 patients undergoing robot‐assisted partial nephrectomy for renal tumors at a single institution between November 2018 and May 2021. The endpoints were how often and how long the surgeon consulted the three‐dimensional‐printed model, determined using intraoperative video. Multivariate analyses of the endpoints were adjusted by preoperative patient and kidney characteristics, including renal vascular complexity that was defined as the number of vascular branches penetrating the surface tangential to the ventral side of the kidney.
Results
Of the 93 cases, the median frequency and duration of intraoperative three‐dimensional‐printed model consultation were four times and 39 s, respectively. The multivariate linear regression analyses showed that the frequency of intraoperative three‐dimensional‐printed model consultation by the surgeon was significantly related to the complexity of the arterial structure (≥4 branches), presence of hilar tumor, and high Mayo Adhesive Probability score; the regression coefficients were 1.81, 2.79, and 1.34, respectively. All p ‐values were ≤.03. The duration of the three‐dimensional‐printed model consultation was significantly related to the complexity of the arterial structure (≥4 branches) and the presence of hilar tumor; the regression coefficients were 21.6, and 29.0 s, respectively. All p ‐values were
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Sano Kosei General Hospital, Tochigi, Japan.
- Department of Urology, Jichi Medical University, Tochigi, Japan.
- Department of Urology, International University of Health and Welfare Hospital, Tochigi, Japan.
- Department of Radiology, Jichi Medical University, Tochigi, Japan.
- Department of Urology, Tochigi Medical Center Shimotsuga, Tochigi, Japan.
ORCID-Profile: Masahiro Yamazaki, Tetsuya Fujimura
Zitieren
APA
Yamazaki, M., Takayama, T., Sugihara, T., Kikuchi, T., Kamimura, T., Kamei, J., Ando, S., Terauchi, F., Morita, T., & Fujimura, T. (2024). Factors affecting the use of a three‐dimensional model during robot‐assisted partial nephrectomy. Asian Journal of Endoscopic Surgery. https://doi.org/10.1111/ases.13301
Vancouver
Yamazaki M, Takayama T, Sugihara T, Kikuchi T, Kamimura T, Kamei J, et al. Factors affecting the use of a three‐dimensional model during robot‐assisted partial nephrectomy. Asian Journal of Endoscopic Surgery. 2024. doi:10.1111/ases.13301
BibTeX
@article{Yamazaki2024,
author = {Yamazaki, Masahiro and Takayama, Tatsuya and Sugihara, Toru and Kikuchi, Tomohiro and Kamimura, Tomoki and Kamei, Jun and Ando, Satoshi and Terauchi, Fumihito and Morita, Tatsuo and Fujimura, Tetsuya},
title = {Factors affecting the use of a three‐dimensional model during robot‐assisted partial nephrectomy},
journal = {Asian Journal of Endoscopic Surgery},
year = {2024},
doi = {10.1111/ases.13301}
}
EUVIMED