Bleb morphology after trabeculectomy: A comparison of the Indiana Bleb Appearance Grading Scale and three‐dimensional anterior segment optical coherence tomography
Acta Ophthalmologica · 2026
DOI: 10.1111/aos.70026 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Ophthalmologica, 2026. Verfasst von Afrouz Ahmadzadeh und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Trabeculectomy, Tomography, Optical Coherence, Anterior Eye Segment, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Henry og Astrid Møllers Fond, Gangsted Fond, Synoptik-Fonden.
Abstract (Originalsprache)
Purpose
To compare bleb morphology after trabeculectomy using a visual grading system, the Indiana Bleb Appearance Grading Scale (IBAGS) and anterior segment optical coherence tomography (AS‐OCT).
Methods
Fifty‐seven patients who underwent trabeculectomy were included in this study. Clinical evaluations of the bleb and imaging with anterior segment OCT were conducted 12 months postoperatively. Bleb assessments were performed using a slit‐lamp microscope with the IBAGS and a 3D AS‐OCT CASIA2.
Results
Bleb height evaluations from IBAGS and AS‐OCT measurements showed a moderate positive correlation ( p = 0.03), indicating alignment between the two systems. IBAGS variables explained about 16% of the variance in IOP, with a significant negative relationship between bleb height and IOP (for each unit increase in bleb height, IOP decreased by 1.9 mmHg; p = 0.03). The overall model fit was significant for IBAGS ( p = 0.03) but not for AS‐OCT ( p = 0.2), suggesting that IBAGS may be more relevant for predicting IOP.
Conclusion
IBAGS demonstrated a stronger association with IOP, suggesting its greater relevance in assessing trabeculectomy bleb morphology for predicting surgical success. Additionally, we found a significant correlation between bleb height measurements obtained from IBAGS and the AS‐OCT system. By integrating both systems, a more comprehensive approach to monitoring bleb function can be achieved, ultimately improving the accuracy of postoperative glaucoma management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
- Department of Ophthalmology, Okayama Saiseikai General Hospital, Okayama, Japan.
- Department of Physics and Astronomy, University of California, Irvine, California, USA.
- Department of Ophthalmology, Kurashiki Medical Center, Kurashiki, Okayama, Japan.
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
ORCID-Profile: Afrouz Ahmadzadeh, Kae Sugihara, Line Kessel, Daniella Bach-Holm
Förderung
- Henry og Astrid Møllers Fond
- Gangsted Fond
- Synoptik-Fonden
- Aase og Ejnar Danielsens Fond
- Fabrikant Einar Willumsens Fond
- The Danish Eye Research Foundation
- Fight for Sight Denmark
Zitieren
APA
Ahmadzadeh, A., Narita, A., Simmendefeldt Schmidt, B., Sugihara, K., Kessel, L., Miyake, T., & Bach-Holm, D. (2026). Bleb morphology after trabeculectomy: A comparison of the Indiana Bleb Appearance Grading Scale and three‐dimensional anterior segment optical coherence tomography. Acta Ophthalmologica. https://doi.org/10.1111/aos.70026
Vancouver
Ahmadzadeh A, Narita A, Simmendefeldt Schmidt B, Sugihara K, Kessel L, Miyake T, et al. Bleb morphology after trabeculectomy: A comparison of the Indiana Bleb Appearance Grading Scale and three‐dimensional anterior segment optical coherence tomography. Acta Ophthalmologica. 2026. doi:10.1111/aos.70026
BibTeX
@article{Ahmadzadeh2026,
author = {Ahmadzadeh, Afrouz and Narita, Akiko and Simmendefeldt Schmidt, Bo and Sugihara, Kae and Kessel, Line and Miyake, Tomoe and Bach-Holm, Daniella},
title = {Bleb morphology after trabeculectomy: A comparison of the Indiana Bleb Appearance Grading Scale and three‐dimensional anterior segment optical coherence tomography},
journal = {Acta Ophthalmologica},
year = {2026},
doi = {10.1111/aos.70026}
}
EUVIMED