Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations

Toke Bek iD, Giovanni Ometto iD

Acta Ophthalmologica · 2026

DOI: 10.1111/aos.17566 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2026. Verfasst von Toke Bek und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. Hauptthemen laut MEDLINE: Photography, Algorithms, Retina. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Imaging of the retina is accompanied by distortions so that positions in fundus photographs cannot be linearly translated to positions in the retinal fundus. The purpose of this study was to describe an algorithm and evaluate its reproducibility in identifying points on the retina from their representation on serial fundus photographs.

Methods

A mathematical formalism was derived to describe how the location of the fovea and the optic disc in fundus photographs, together with the centre‐nodal point distance ( d ) and the curvature radius ( r ) of the eye, can be used to calculate spatial coordinates on the retina that correspond to given locations in the photograph. The effect of manual markings of the fovea and the optic disc as reference points was evaluated, and the formalism was tested on 105 photographs recorded with different image modalities and centring from 10 different patients.

Results

Retinal locations could be identified in serial fundus photographs with a reproducibility of at least 50 μm when the centre‐nodal point distance and the curvature radius were set to those in Gullstrand's standard eye. A main source of the variability was the manual identification of the fovea and optic disc used as reference points.

Conclusions

The reproducibility in the identification of locations on the retina from serial fundus photographs depends on the accuracy in the definition of the fovea and optic disc used as reference points. This affects the potential for describing locations, distances, areas and changes in retinal lesions on serial photographs over time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotographyAlgorithmsRetinaHumansReproducibility of ResultsFundus OculiOptic DiskFovea Centralis

Stichwörter der Autor:innen

fundus photographyimage processingoptical distortionretinopathy grading

Autor:innen und Institutionen

  • Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark.
  • City University of London, London, UK.

ORCID-Profile: Toke Bek, Giovanni Ometto

Zitieren

APA

Bek, T., & Ometto, G. (2026). Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations. Acta Ophthalmologica. https://doi.org/10.1111/aos.17566

Vancouver

Bek T, Ometto G. Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations. Acta Ophthalmologica. 2026. doi:10.1111/aos.17566

BibTeX
@article{Bek2026,
  author = {Bek, Toke and Ometto, Giovanni},
  title = {Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations},
  journal = {Acta Ophthalmologica},
  year = {2026},
  doi = {10.1111/aos.17566}
}
Kostenlos starten →