Validation of the European visual field standards for driving: A driving simulator‐based study
Acta Ophthalmologica · 2025
DOI: 10.1111/aos.16783 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Acta Ophthalmologica, 2025. Verfasst von Thea Melsen Sudmann und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Oslo University Hospital, Oslo, Norway. Hauptthemen laut MEDLINE: Visual Fields, Visual Field Tests, Automobile Driving, Computer Simulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Norwegian Glaucoma Research Foundation, Arthur and Odd Clauson's Legacy, Oslo University Hospital.
Abstract (Originalsprache)
Purpose
To determine whether we could establish evidence‐based pass/fail criteria for perimetry in the context of the European visual field standards for driving.
Methods
This two‐centre, cross‐sectional study included participants with binocular visual field loss that had led to revocation of a group‐1 driving licence. The participants underwent cognitive and binocular visual testing, including the European Driving Test (EDT), a perimetry algorithm that adheres to the European visual field standards. We used a high‐fidelity driving simulator to compare the driving ability of these participants with healthy controls. Two driving instructors classified each driving test as passed or failed. Receiver operating characteristic (ROC) analysis and area under the curve (AUC) determined the ability of perimetry to discriminate between passed and failed driving tests.
Results
The study included 70 participants with visual field loss and 37 controls. A non‐significantly higher proportion of controls passed the driving test (75% vs. 63%; p = 0.22). In ROC analysis, contrast sensitivity performed best (AUC of 0.73), followed by NEI VFQ‐25 (AUC of 0.64). Peripheral visual field (AUC of 0.56) and central visual field (AUC of 0.47) performed weaker. Combining the central and peripheral visual field, and their interaction, increased AUC to 0.63.
Conclusion
Perimetry was a poor predictor of simulator‐based driving test result, and we could not establish appropriate pass/fail criteria for the European visual field standards. Because perimetry is not an accurate diagnostic tool for fitness to drive, a practical driving assessment should be performed in case of doubt.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Oslo University Hospital, Oslo, Norway.
- Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
- Department of Ophthalmology, Drammen Hospital, Drammen, Norway.
- Department of Ophthalmology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
- Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.
- Huq Industries, London, UK.
ORCID-Profile: Thea Melsen Sudmann, Anna Torblaa, Dordi Austeng, Tomas Bro, Fiona Rowe, Øystein Kalsnes Jørstad
Förderung
- The Norwegian Glaucoma Research Foundation
- Arthur and Odd Clauson's Legacy
- Oslo University Hospital
- The Norwegian Association of the Blind
- Oslo universitetssykehus HF
Zitieren
APA
Sudmann, T. M., Torblaa, A., Austeng, D., Reshodko, I., Rehm, J., Bro, T., Brækhus, A., Klungsøyr, O., Rowe, F., & Jørstad, Ø. K. (2025). Validation of the European visual field standards for driving: A driving simulator‐based study. Acta Ophthalmologica. https://doi.org/10.1111/aos.16783
Vancouver
Sudmann TM, Torblaa A, Austeng D, Reshodko I, Rehm J, Bro T, et al. Validation of the European visual field standards for driving: A driving simulator‐based study. Acta Ophthalmologica. 2025. doi:10.1111/aos.16783
BibTeX
@article{Sudmann2025,
author = {Sudmann, Thea Melsen and Torblaa, Anna and Austeng, Dordi and Reshodko, Irina and Rehm, Johannes and Bro, Tomas and Brækhus, Anne and Klungsøyr, Ole and Rowe, Fiona and Jørstad, Øystein Kalsnes},
title = {Validation of the European visual field standards for driving: A driving simulator‐based study},
journal = {Acta Ophthalmologica},
year = {2025},
doi = {10.1111/aos.16783}
}
EUVIMED