Vision screening and refraction of Greenlandic schoolchildren
Acta Ophthalmologica · 2025
DOI: 10.1111/aos.16740 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Acta Ophthalmologica, 2025. Verfasst von Nick Duelund und 4 weiteren Autor:innen. Beteiligte Einrichtung: Queen Ingrids Healthcare Center, Nuuk, Greenland. Hauptthemen laut MEDLINE: Amblyopia, Refraction, Ocular, Refractive Errors, Vision Screening. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To estimate the prevalence of amblyopia and refractive errors among 6‐year‐old children in Greenland and to assess the impact of incorporating autorefraction, stereoacuity and near visual acuity testing into vision screening.
Methods
In this cross‐sectional study, 517 children (238 girls and 279 boys) from 21 locations in Greenland were screened using HOTV charts for distance and near visual acuity (VA), stereoacuity test and non‐cycloplegic autorefraction. Referral criteria for further ophthalmological examination included a VA of ≥0.2 logMAR on the worse‐seeing eye or an interocular VA difference of ≥2 lines.
Results
Initial screening identified amblyopia (defined as VA of ≥0.3 logMAR) in 7% (unilateral) and 3% (bilateral) of children. However, subsequent ophthalmological examinations confirmed amblyopia in under 40% of referrals. Significant interocular VA differences were found in 9%. The prevalence of refractive errors at the screening was 3% for myopia (≤−0.5 dioptres), 10% for hyperopia (>+2.0 dioptres) and 14% for astigmatism (≤−1.00 dioptres), while the corresponding prevalences at the ophthalmological examination were 4% for myopia, 8% for hyperopia and 6% for astigmatism. Combining screening measurements increased the positive predictive values, thereby enhancing screening accuracy. Specifically, the incorporation of autorefraction or stereoacuity with distance VA demonstrated to be the most effective combination. Six percent of the children were prescribed glasses after the screening procedure.
Conclusion
This study provides the first visual profile of Greenlandic schoolchildren. Incorporating autorefraction, stereoacuity and near visual acuity in vision screenings enhanced the efficacy of detection of vision anomalies. Although this may lead to more false positives, accurate screening is crucial in regions with limited ophthalmological resources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Queen Ingrids Healthcare Center, Nuuk, Greenland.
- Greenland Center of Health Research, Institute of Health and Nature, Ilisimatusarfik University of Greenland, Nuuk, Greenland.
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark.
- University of Copenhagen, Copenhagen, Denmark.
- Danish College of Optometry and Vision Science, Dania Academy, Randers, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
ORCID-Profile: Nick Duelund, Ivan Nisted, Steffen Heegaard
Zitieren
APA
Duelund, N., Nisted, I., Jørgensen, M. E., Heegaard, S., & Jensen, H. (2025). Vision screening and refraction of Greenlandic schoolchildren. Acta Ophthalmologica. https://doi.org/10.1111/aos.16740
Vancouver
Duelund N, Nisted I, Jørgensen ME, Heegaard S, Jensen H. Vision screening and refraction of Greenlandic schoolchildren. Acta Ophthalmologica. 2025. doi:10.1111/aos.16740
BibTeX
@article{Duelund2025,
author = {Duelund, Nick and Nisted, Ivan and Jørgensen, Marit Eika and Heegaard, Steffen and Jensen, Hanne},
title = {Vision screening and refraction of Greenlandic schoolchildren},
journal = {Acta Ophthalmologica},
year = {2025},
doi = {10.1111/aos.16740}
}
EUVIMED