Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes
Acta Ophthalmologica · 2024
DOI: 10.1111/aos.16654 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Haorui Yuan und 11 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangong, China. Hauptthemen laut MEDLINE: Anterior Chamber, Lenses, Intraocular, Biometry, Axial Length, Eye. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Construction Project of High-Level Hospitals in Guangdong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To evaluate the performance of intraocular lens (IOL) calculation formulas and the effect of anterior chamber depth (ACD), axial length (AL) and lens thickness (LT) on the prediction accuracy in shallow ACD eyes.
Methods
This retrospective, consecutive case‐series study included 648 eyes of 648 patients with an ACD < 3.0 mm who underwent phacoemulsification and IOL implantation. Eleven formulas were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Hill‐Radial Basis Function (RBF) 3.0, Hoffer QST, Kane, Olsen, Pearl‐DGS and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T). Subgroup analysis was performed based on ACD, AL and LT.
Results
Overall, the Hoffer QST and Kane showed no systematic bias. The Kane, EVO 2.0, Hill‐RBF 3.0 and Hoffer QST had relatively lower mean absolute error and higher percentages of prediction error within ±0.5 D. For the ACD of 2.5–3.0 mm and AL < 22.0 mm subgroup, the Pearl‐DGS exhibited the lowest MAE (0.45 D) and MedAE (0.41 D). Most formulas had a significant myopic bias (−0.43 to −0.18 D, p < 0.05) in the LT < 4.3 mm subgroup and a significant hyperopic bias (0.09–0.29 D, p < 0.05) in the LT ≥ 5.1 mm subgroup.
Conclusion
The Kane and Hoffer QST were recommended for shallow ACD eyes. In eyes with an ACD between 2.5 and 3.0 mm and a short AL, the Pearl‐DGS showed excellent performance. Clinicians need to fine‐tune the target refraction according to LT in shallow ACD eyes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangong, China.
- Zhongshan Medical School, Sun Yat-sen University, Guangzhou, Guangdong, China.
ORCID-Profile: Haorui Yuan, Xiaotong Han, Yiguo Huang
Förderung
- Construction Project of High-Level Hospitals in Guangdong Province
- National Natural Science Foundation of China
Zitieren
APA
Yuan, H., Zhang, J., Han, X., Ye, J., Huang, Y., Huang, R., Wen, L., Qiu, X., Chen, X., Chen, K., Tan, X., & Luo, L. (2024). Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes. Acta Ophthalmologica. https://doi.org/10.1111/aos.16654
Vancouver
Yuan H, Zhang J, Han X, Ye J, Huang Y, Huang R, et al. Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes. Acta Ophthalmologica. 2024. doi:10.1111/aos.16654
BibTeX
@article{Yuan2024,
author = {Yuan, Haorui and Zhang, Jiaqing and Han, Xiaotong and Ye, Jinfeng and Huang, Yiguo and Huang, Ruoxuan and Wen, Ling and Qiu, Xiaozhang and Chen, Xiaoyun and Chen, Kailin and Tan, Xuhua and Luo, Lixia},
title = {Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes},
journal = {Acta Ophthalmologica},
year = {2024},
doi = {10.1111/aos.16654}
}
EUVIMED