EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Microaneurysm detection using high‐speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy

Kim Lien Huber iD, Heiko Stino iD, Thomas Schlegl, Irene Steiner, Gergely Nagy, Michael Niederleithner, Bernhard Baumann, Wolfgang Drexler, Rainer A Leitgeb, Ursula Schmidt-Erfurth iD, Tilman Schmoll, Andreas Pollreisz iD

Acta Ophthalmologica · 2024

DOI: 10.1111/aos.16619 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Kim Lien Huber und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Diabetic Retinopathy, Tomography, Optical Coherence, Microaneurysm, Fluorescein Angiography. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Horizon 2020 Framework Program H2020-ICT-2016-1.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare detection rates of microaneurysms (MAs) on high‐speed megahertz optical coherence tomography angiography (MHz‐OCTA), fluorescein angiography (FA) and colour fundus photography (CF) in patients with diabetic retinopathy (DR).

Methods

For this exploratory cross‐sectional study, MHz‐OCTA data were acquired with a swept‐source OCT prototype (A‐scan rate: 1.7 MHz), and FA and CF imaging was performed using Optos® California. MA count was manually evaluated on en face MHz‐OCTA/FA/CF images within an extended ETDRS grid. Detectability of MAs visible on FA images was evaluated on corresponding MHz‐OCTA and CF images. MA distribution and leakage were correlated with detectability on OCTA and CF imaging.

Results

47 eyes with severe DR ( n = 12) and proliferative DR ( n = 35) were included. MHz‐OCTA and CF imaging detected on average 56% and 36% of MAs, respectively. MHz‐OCTA detection rate was significantly higher than CF ( p < 0.01). The combination of MHz‐OCTA and CF leads to an increased detection rate of 70%. There was no statistically significant association between leakage and MA detectability on OCTA ( p = 0.13). For CF, the odds of detecting leaking MAs were significantly lower than non‐leaking MAs ( p = 0.012). Using MHz‐OCTA, detection of MAs outside the ETDRS grid was less likely than MAs located within the ETDRS grid (outer ring, p < 0.01; inner ring, p = 0.028). No statistically significant difference between rings was observed for CF measurements.

Conclusions

More MAs were detected on MHz‐OCTA than on CF imaging. Detection rate was lower for MAs located outside the macular region with MHz‐OCTA and for leaking MAs with CF imaging. Combining both non‐invasive modalities can improve MA detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetic RetinopathyTomography, Optical CoherenceMicroaneurysmFluorescein AngiographyRetinal VesselsFundus OculiHumansCross-Sectional StudiesMaleFemaleMiddle AgedAged

Stichwörter der Autor:innen

OCTAdetectiondiabetic retinopathyleakagemicroaneurysms

Autor:innen und Institutionen

  • Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.
  • Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
  • Center for Medical Data Science, Institute of Medical Statistics, Medical University of Vienna, Vienna, Austria.
  • Carl Zeiss Meditec, Inc., Dublin, California, USA.

ORCID-Profile: Kim Lien Huber, Heiko Stino, Ursula Schmidt-Erfurth, Andreas Pollreisz

Förderung

  • Horizon 2020 Framework Program H2020-ICT-2016-1

Zitieren

APA

Huber, K. L., Stino, H., Schlegl, T., Steiner, I., Nagy, G., Niederleithner, M., Baumann, B., Drexler, W., Leitgeb, R. A., Schmidt-Erfurth, U., Schmoll, T., & Pollreisz, A. (2024). Microaneurysm detection using high‐speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy. Acta Ophthalmologica. https://doi.org/10.1111/aos.16619

Vancouver

Huber KL, Stino H, Schlegl T, Steiner I, Nagy G, Niederleithner M, et al. Microaneurysm detection using high‐speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy. Acta Ophthalmologica. 2024. doi:10.1111/aos.16619

BibTeX
@article{Huber2024,
  author = {Huber, Kim Lien and Stino, Heiko and Schlegl, Thomas and Steiner, Irene and Nagy, Gergely and Niederleithner, Michael and Baumann, Bernhard and Drexler, Wolfgang and Leitgeb, Rainer A and Schmidt-Erfurth, Ursula and Schmoll, Tilman and Pollreisz, Andreas},
  title = {Microaneurysm detection using high‐speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy},
  journal = {Acta Ophthalmologica},
  year = {2024},
  doi = {10.1111/aos.16619}
}
Kostenlos starten →