EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Impact of cleanroom status on the reasons for discarding organ‐cultured corneal transplants in a modern eye bank – More donor corneas thanks to astronaut suit?

Marco Zilles iD, Elias Flockerzi iD, Loay Daas, Isabel Weinstein, Loic Hamon iD, Berthold Seitz

Acta Ophthalmologica · 2024

DOI: 10.1111/aos.16611 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Marco Zilles und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University Hospital of the Saarland (UKS), Homburg, Germany. Hauptthemen laut MEDLINE: Eye Banks, Tissue Donors, Corneal Transplantation. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study investigated the influence of cleanroom conditions on the discard rates of donor corneas in a German university eye bank.

Methods

Discard rates were analysed from 2017 to 2020 at the LIONS Cornea Bank at Saarland University Medical Center. 1941 corneas from 971 donors were included. 1262 corneas (65.1%) were stored in a class D cleanroom from 2017 to 2019 and processed in a cleanroom class A sterile bank (group 1). 679 corneas (34.9%) were continuously stored in a class B cleanroom and processed in a class A cleanroom safety cabinet in the same room from 2019 to 2020 (group 2). The target parameter of this work was the number of contamination‐related discards. Although they cannot be influenced by the spatial conditions, the discards due to insufficient endothelial quality, serology, contraindications, scars and technical causes were also recorded. Statistical analysis was performed using SPSS and various testing procedures.

Results

In group 1, significantly more corneas were discarded due to positive serology (6.9%|3.8%, p = 0.020). There was no significant change between both groups for either contamination or the other reasons for discard.

Conclusion

Optimization of hygiene standards from cleanroom class D to B did not reduce contamination. Serology, endothelial quality, medical contraindications and the presence of scars cannot be influenced by cleanroom conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eye BanksTissue DonorsCorneal TransplantationHumansGermanyCorneaOrgan Culture TechniquesOrgan PreservationRetrospective StudiesFemaleMaleTissue and Organ Procurement

Stichwörter der Autor:innen

cornea bankcorneal donorcorneal transplantationdiscard rate

Autor:innen und Institutionen

  • Department of Ophthalmology, University Hospital of the Saarland (UKS), Homburg, Germany.

ORCID-Profile: Marco Zilles, Elias Flockerzi, Loic Hamon

Zitieren

APA

Zilles, M., Flockerzi, E., Daas, L., Weinstein, I., Hamon, L., & Seitz, B. (2024). Impact of cleanroom status on the reasons for discarding organ‐cultured corneal transplants in a modern eye bank – More donor corneas thanks to astronaut suit?. Acta Ophthalmologica. https://doi.org/10.1111/aos.16611

Vancouver

Zilles M, Flockerzi E, Daas L, Weinstein I, Hamon L, Seitz B. Impact of cleanroom status on the reasons for discarding organ‐cultured corneal transplants in a modern eye bank – More donor corneas thanks to astronaut suit?. Acta Ophthalmologica. 2024. doi:10.1111/aos.16611

BibTeX
@article{Zilles2024,
  author = {Zilles, Marco and Flockerzi, Elias and Daas, Loay and Weinstein, Isabel and Hamon, Loic and Seitz, Berthold},
  title = {Impact of cleanroom status on the reasons for discarding organ‐cultured corneal transplants in a modern eye bank – More donor corneas thanks to astronaut suit?},
  journal = {Acta Ophthalmologica},
  year = {2024},
  doi = {10.1111/aos.16611}
}
Kostenlos starten →