Comparison of surgical outcomes of Carlevale sutureless scleral fixation and Artisan Aphakia intraocular lens
Acta Ophthalmologica · 2024
DOI: 10.1111/aos.15795 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von V Van Severen und 6 weiteren Autor:innen. Beteiligte Einrichtung: HagaHospital, The Hague, The Netherlands. Hauptthemen laut MEDLINE: Sclera, Visual Acuity, Refraction, Ocular, Sutureless Surgical Procedures. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To compare intra‐ and postoperative results of sutureless scleral fixated Carlevale intraocular lens (IOL) with iris fixated Artisan IOL.
Methods
Monocentre, retrospective analysis of refractive outcomes and intra‐ and postoperative complications of patients who received a Carlevale or Artisan IOL between January 2019 and March 2022.
Results
178 eyes of 169 patients were included (101 Carlevale and 77 Artisan IOLs). The standard follow‐up time was 1 month. Two statistically significant differences were found: in the deviation of the postoperative spherical equivalent of the refraction from the preoperative chosen IOL target ( p = 0.019; mean deviation was −0.46 in the Carlevale and 0.08 in the Artisan group), and the number of eyes with complications between the Carlevale and Artisan groups ( p = 0.003; 33 in the Carlevale and 42 in the Artisan group).
Conclusion
The current study is the largest so far comparing both refractive outcomes and complications after implantation of Carlevale and Artisan IOL. The Carlevale IOL does not carry a greater complication risk on the short‐term follow‐up. This provides additional evidence that the Carlevale IOL has to be added to the armamentarium of the ophthalmic surgeon.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- HagaHospital, The Hague, The Netherlands.
- Leiden University Medical Center, Leiden, The Netherlands.
- Retina Operatiecentrum, Amstelveen, The Netherlands.
ORCID-Profile: V Van Severen, G Bamonte
Zitieren
APA
Van Severen, V., Maaijwee, K. J. M., Pennekamp, C. W. A., Feenstra, H. M. A., van Dijk, E. H. C., Lindstedt, E. W., & Bamonte, G. (2024). Comparison of surgical outcomes of Carlevale sutureless scleral fixation and Artisan Aphakia intraocular lens. Acta Ophthalmologica. https://doi.org/10.1111/aos.15795
Vancouver
Van Severen V, Maaijwee KJM, Pennekamp CWA, Feenstra HMA, van Dijk EHC, Lindstedt EW, et al. Comparison of surgical outcomes of Carlevale sutureless scleral fixation and Artisan Aphakia intraocular lens. Acta Ophthalmologica. 2024. doi:10.1111/aos.15795
BibTeX
@article{VanSeveren2024,
author = {Van Severen, V and Maaijwee, K J M and Pennekamp, C W A and Feenstra, H M A and van Dijk, E H C and Lindstedt, E W and Bamonte, G},
title = {Comparison of surgical outcomes of Carlevale sutureless scleral fixation and Artisan Aphakia intraocular lens},
journal = {Acta Ophthalmologica},
year = {2024},
doi = {10.1111/aos.15795}
}
EUVIMED